EUVIMEDEUVIMED entdecken
Vergleichsstudie

Cataract surgery using two 3D visualization systems: Complication rates, surgical duration & comparison with traditional microscopes

Vasilios F Diakonis iD, Konstantinos T Tsaousis iD, Caroline Watson, Kirk Castellano, Robert J Weinstock

European Journal of Ophthalmology · 2024

DOI: 10.1177/11206721241237298 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift European Journal of Ophthalmology, 2024. Verfasst von Vasilios F Diakonis und 4 weiteren Autor:innen. Beteiligte Einrichtung: The Eye Institute of West Florida, Largo, Florida, USA. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Microscopy, Operative Time. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare the complication rates and surgical duration of cataract surgery using two 3D visualization systems and a traditional binocular microscope among experienced and inexperienced surgeons.

Methods

This retrospective case series included 571 eyes that received cataract surgery using either heads up cataract surgery, via a 3D head mounted system ( N = 148–Group 1) or a 3D display screen ( N = 338 eyes–Group 2), or traditional binocular microscope ( N = 85 eyes–Group 3). The surgical records of consecutive patients who underwent cataract surgery by two groups of surgeons (experienced and inexperienced) were reviewed. Patients in all groups received either femtosecond laser assisted cataract surgery (FLACS) or traditional phacoemulsification. Complication rate, as well as duration of cataract surgery were evaluated between all three visualization approaches, between experienced and inexperienced surgeons.

Results

There was no statistically significant difference in duration of surgery between all 3 visualization approaches for both experienced and inexperienced surgeons ( p < 0.05). Furthermore, the type of surgical technique (manual or FLACS) did not affect the surgical duration for both experienced and inexperienced surgeons ( p < 0.05). No intraoperative complications were demonstrated in the current cohort.

Conclusions

The implementation of heads up–3D visualization either through a screen or a head mounted platform for cataract surgery seems to offer similar safety and efficiency as the traditional binocular microscope, and both experienced and inexperienced surgeons demonstrate the same outcomes in terms of safety and efficiency.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Imaging, Three-DimensionalMicroscopyOperative TimeHumansRetrospective StudiesMaleFemaleAgedPostoperative ComplicationsCataract ExtractionIntraoperative ComplicationsMiddle AgedVisual AcuityClinical CompetencePhacoemulsificationAged, 80 and overLaser TherapyLens Implantation, Intraocular

Stichwörter der Autor:innen

Lens / cataractclear lens extraction < lens / cataractintraoperative complications of cataract surgery < lens / cataractphacoemulsificationsurgical instruments / special techniques < lens / cataract

Autor:innen und Institutionen

  • The Eye Institute of West Florida, Largo, Florida, USA.

ORCID-Profile: Vasilios F Diakonis, Konstantinos T Tsaousis

Zitieren

APA

Diakonis, V. F., Tsaousis, K. T., Watson, C., Castellano, K., & Weinstock, R. J. (2024). Cataract surgery using two 3D visualization systems: Complication rates, surgical duration & comparison with traditional microscopes. European Journal of Ophthalmology. https://doi.org/10.1177/11206721241237298

Vancouver

Diakonis VF, Tsaousis KT, Watson C, Castellano K, Weinstock RJ. Cataract surgery using two 3D visualization systems: Complication rates, surgical duration & comparison with traditional microscopes. European Journal of Ophthalmology. 2024. doi:10.1177/11206721241237298

BibTeX
@article{Diakonis2024,
  author = {Diakonis, Vasilios F and Tsaousis, Konstantinos T and Watson, Caroline and Castellano, Kirk and Weinstock, Robert J},
  title = {Cataract surgery using two 3D visualization systems: Complication rates, surgical duration & comparison with traditional microscopes},
  journal = {European Journal of Ophthalmology},
  year = {2024},
  doi = {10.1177/11206721241237298}
}
Kostenlos starten →