EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC 4.0

Comparison of Camera-Acquired Vital Signs to Conventional Vital Signs in a Space-Analog Environment

Carlo A Canepa iD, Dana R Levin, Amit S Padaki iD

Wilderness & Environmental Medicine · 2025

DOI: 10.1177/10806032241291994 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Wilderness & Environmental Medicine, 2025. Verfasst von Carlo A Canepa und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Emergency Medicine, Baylor College of Medicine, Houston, TX, USA. Hauptthemen laut MEDLINE: Vital Signs, Photography, Respiratory Rate, Heart Rate. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Vital sign acquisition is a key component of modern medical care. In wilderness and space medical settings, vital sign acquisition can be a difficult process because of limitations on available personnel or lack of access to the patient. Camera-acquired vital signs could address each of these difficulties.

Methods

Healthy volunteers used software designed by Presage Technologies to acquire heart rate and respiratory rate at the HI-SEAS space-analog site in Mauna Loa, Hawai’i. Camera-acquired vital signs were compared to more conventionally acquired vital signs.

Results

Camera-acquired heart rate showed high correlation to conventionally acquired heart rate (R ∼ 0.95). Camera-acquired respiratory rate showed moderate correlation (R ∼ 0.65).

Conclusions

These results show that camera acquisition of vital signs is theoretically feasible in wilderness and space-analog environments. HR may be highly accurate even using current technology. Additional studies will be needed to further validate other types of camera sensors and other potential environments such as partial gravity and microgravity.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Vital SignsPhotographyRespiratory RateHeart RateWilderness MedicineVideo RecordingHumansMaleAdultFemaleHawaiiMonitoring, PhysiologicMiddle Aged

Stichwörter der Autor:innen

cameranoncontactspace analogvital signswilderness medicine

Autor:innen und Institutionen

  • Department of Emergency Medicine, Baylor College of Medicine, Houston, TX, USA.

ORCID-Profile: Carlo A Canepa, Amit S Padaki

Zitieren

APA

Canepa, C. A., Levin, D. R., & Padaki, A. S. (2025). Comparison of Camera-Acquired Vital Signs to Conventional Vital Signs in a Space-Analog Environment. Wilderness & Environmental Medicine. https://doi.org/10.1177/10806032241291994

Vancouver

Canepa CA, Levin DR, Padaki AS. Comparison of Camera-Acquired Vital Signs to Conventional Vital Signs in a Space-Analog Environment. Wilderness & Environmental Medicine. 2025. doi:10.1177/10806032241291994

BibTeX
@article{Canepa2025,
  author = {Canepa, Carlo A and Levin, Dana R and Padaki, Amit S},
  title = {Comparison of Camera-Acquired Vital Signs to Conventional Vital Signs in a Space-Analog Environment},
  journal = {Wilderness & Environmental Medicine},
  year = {2025},
  doi = {10.1177/10806032241291994}
}
Kostenlos starten →