EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Development and assessment of autoverification system for routine coagulation assays in inpatient and outpatient settings of tertiary care hospital: algorithm performance and impact on laboratory efficiency

Orakan Limpornpugdee iD, Surapat Tanticharoenkarn iD, Tapakorn Thepnarin, Manissara Yeekaday, Pitchayaporn Riyagoon, Waroonkarn Laiklang, Piyapat Limprapassorn, Eakachai Prompetchara iD

Diagnosis · 07.08.2025 · 12 (3) · 452-463

DOI: 10.1515/dx-2025-0004 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnosis, online erschienen am 03.03.2025. Verfasst von Orakan Limpornpugdee und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand. Hauptthemen laut MEDLINE: Algorithms. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Grants for Development of New Faculty Staff, Ratchadaphiseksomphot Fund, Chulalongkorn University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

This study aimed to develop and implement autoverification (AV) system for routine coagulation assays, specifically prothrombin time (PT) and activated partial thromboplastin time (APTT), in tertiary care hospital. The efficiency, accuracy, and impact on turnaround time (TAT) were evaluated .

Methods

AV rules were developed using historical data from 70,865 coagulation test results. The rules included pre-analytical, analytical, and post-analytical checks. The system underwent validation through data simulations, pilot phase, go-live implementation. Performance metrics included sensitivity, specificity, predictive values, passing rates, error rates, TAT.

Results

The AV system achieved 63.3 % overall passing rate (analyzed from 159,183 data), with outpatient settings showing higher rate (69.2 %) than inpatient settings (56.3 %). Final performance evaluation showed sensitivity, specificity, PPV, and NPV of 93.0 , 65.0, 59.7, and 94.4 %, respectively. Manual verification was required for 36 % of cases, mainly due to defective sample volumes (21.5 %). False negatives, primarily from partial clots, occurred in 0.1 % of cases. Integrating CBC clot alerts into AV rules halved the errors. The system increased tests completed within guaranteed TAT of 90 min by 2.4 %, from 89.7 to 92.1 % and reduced median TAT by 5 min. Outpatient TAT improved significantly, with a reduction over 19 min.

Conclusions

The AV system for APTT and PT tests was successfully implemented, reducing manual verification, improving TAT, particularly in outpatient settings. This study highlights AV systems’ potential to enhance laboratory performance for routine coagulation panels, which rely only on APTT and PT assays. Ongoing rule refinement and monitoring remain crucial for enhancing system accuracy and effectiveness.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

AlgorithmsHumansTertiary Care CentersPartial Thromboplastin TimeProthrombin TimeBlood Coagulation TestsOutpatientsSensitivity and SpecificityInpatientsReproducibility of Results

Stichwörter der Autor:innen

autovalidationautoverificationcoagulationlaboratory information systemsturnaround time

Autor:innen und Institutionen

  • Department of Laboratory Medicine, Faculty of Medicine, Chulalongkorn University, Bangkok, Thailand.
  • Division of Laboratory Medicine, King Chulalongkorn Memorial Hospital, Bangkok, Thailand.

ORCID-Profile: Orakan Limpornpugdee, Surapat Tanticharoenkarn, Eakachai Prompetchara

Förderung

  • Grants for Development of New Faculty Staff, Ratchadaphiseksomphot Fund, Chulalongkorn University

Zitieren

APA

Limpornpugdee, O., Tanticharoenkarn, S., Thepnarin, T., Yeekaday, M., Riyagoon, P., Laiklang, W., Limprapassorn, P., & Prompetchara, E. (2025). Development and assessment of autoverification system for routine coagulation assays in inpatient and outpatient settings of tertiary care hospital: algorithm performance and impact on laboratory efficiency. Diagnosis, 12(3), 452-463. https://doi.org/10.1515/dx-2025-0004

Vancouver

Limpornpugdee O, Tanticharoenkarn S, Thepnarin T, Yeekaday M, Riyagoon P, Laiklang W, et al. Development and assessment of autoverification system for routine coagulation assays in inpatient and outpatient settings of tertiary care hospital: algorithm performance and impact on laboratory efficiency. Diagnosis. 2025;12(3):452-463. doi:10.1515/dx-2025-0004

BibTeX
@article{Limpornpugdee2025,
  author = {Limpornpugdee, Orakan and Tanticharoenkarn, Surapat and Thepnarin, Tapakorn and Yeekaday, Manissara and Riyagoon, Pitchayaporn and Laiklang, Waroonkarn and Limprapassorn, Piyapat and Prompetchara, Eakachai},
  title = {Development and assessment of autoverification system for routine coagulation assays in inpatient and outpatient settings of tertiary care hospital: algorithm performance and impact on laboratory efficiency},
  journal = {Diagnosis},
  year = {2025},
  volume = {12},
  number = {3},
  pages = {452--463},
  doi = {10.1515/dx-2025-0004}
}
Kostenlos starten →