EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Locking plate fixation with coracoclavicular augmentation through cannulated locking screws for unstable distal clavicle fractures: A retrospective case series

Ji Woong Kim iD, Da Jeong Pak iD, Sung Yoon Jung iD

Journal of Orthopaedic Surgery · 2026-05 · 34 (2)

DOI: 10.1177/10225536261480762 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orthopaedic Surgery, online erschienen am 18.08.2026. Verfasst von Ji Woong Kim und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Dong-A University Hospital, Busan, South Korea. Hauptthemen laut MEDLINE: Clavicle, Fracture Fixation, Internal, Bone Plates, Fractures, Bone. Die Arbeit nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To describe a hybrid fixation technique combining a superior distal clavicle locking plate with coracoclavicular (CC) augmentation through cannulated locking screws and to report its radiological and clinical outcomes.

Methods

We retrospectively reviewed a consecutive surgical cohort treated between March 2022 and March 2025. Of 26 patients who underwent the procedure, 4 were excluded because of follow-up of less than 12 months or loss to follow-up, leaving 22 patients for analysis. Two 2.4-mm × 8.5-mm suture anchors were placed at the conoid and trapezoid footprints of the coracoid base, and the sutures were shuttled from the anteroinferior aspect of the clavicle through cannulated locking screw lumens. Outcomes included union, maintenance of reduction, complications, pain, function, and shoulder motion.

Results

All 22 fractures united at a mean of 12.8 ± 2.5 weeks. The final CC distance ratio was 1.05 ± 0.10. The mean visual analogue scale and QuickDASH scores were 0.6 ± 0.8 and 5.4 ± 2.1, respectively. No coracoid cortical breach, neurovascular injury, implant failure, loss of reduction, or implant removal occurred. Three patients developed transient supraclavicular nerve irritation, which resolved spontaneously.

Conclusion

This technique provided reliable union, maintained reduction, and favorable short-term clinical outcomes. It may provide an anatomically oriented option for supplementary CC stabilization, although comparative and biomechanical studies are required.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

ClavicleFracture Fixation, InternalBone PlatesFractures, BoneBone ScrewsHumansRetrospective StudiesFemaleMaleAdultMiddle AgedAged

Stichwörter der Autor:innen

bonebone platesclaviclefracture fixationfracturesinternalsuture anchors

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Dong-A University Hospital, Busan, South Korea.

ORCID-Profile: Ji Woong Kim, Da Jeong Pak, Sung Yoon Jung

Zitieren

APA

Kim, J. W., Pak, D. J., & Jung, S. Y. (2026). Locking plate fixation with coracoclavicular augmentation through cannulated locking screws for unstable distal clavicle fractures: A retrospective case series. Journal of Orthopaedic Surgery, 34(2). https://doi.org/10.1177/10225536261480762

Vancouver

Kim JW, Pak DJ, Jung SY. Locking plate fixation with coracoclavicular augmentation through cannulated locking screws for unstable distal clavicle fractures: A retrospective case series. Journal of Orthopaedic Surgery. 2026;34(2). doi:10.1177/10225536261480762

BibTeX
@article{Kim2026,
  author = {Kim, Ji Woong and Pak, Da Jeong and Jung, Sung Yoon},
  title = {Locking plate fixation with coracoclavicular augmentation through cannulated locking screws for unstable distal clavicle fractures: A retrospective case series},
  journal = {Journal of Orthopaedic Surgery},
  year = {2026},
  volume = {34},
  number = {2},
  doi = {10.1177/10225536261480762}
}
Kostenlos starten →