EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY-NC 4.0

Similar functional outcomes but different remodeling patterns: A minimum 5-years radiographic comparison of short fit-and-fill stem and quadrangular taper stem

Yasutaka Masada, Tomonori Tetsunaga iD, Kazuo Fujiwara, Kazuki Yamada, Tomohiro Inoue, Ryuichiro Okuda, Tomoko Tetsunaga, Yuki Okazaki iD, Toshifumi Ozaki

Journal of Orthopaedic Surgery · 2026

DOI: 10.1177/10225536261434671 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Journal of Orthopaedic Surgery, 2026. Verfasst von Yasutaka Masada und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopaedic Surgery, Section of Medicine, Division of Medicine, Dentistry and Pharmaceutical Sciences, Graduate School of Medicine, Den…. Hauptthemen laut MEDLINE: Hip Prosthesis, Arthroplasty, Replacement, Hip, Prosthesis Design. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 28 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

ACTIS and CORAIL are cementless titanium femoral stems with hydroxyapatite (HA) coating but differing macro-geometries: ACTIS features a variable triple-taper with a medial collar, whereas CORAIL is a straight double-tapered design available with or without a collar. We compared mid-term clinical and radiographic outcomes of these stems with a minimum 5-years follow-up.

Methods

We retrospectively reviewed 114 primary total hip arthroplasties using ACTIS (63 hips) or CORAIL (51 hips). Clinical outcomes and standardized radiographic parameters were assessed and compared between groups.

Results

The canal-fill ratio (CFR) was significantly greater at the proximal, middle, and distal levels in the ACTIS group. Spot-weld formation was more frequent with ACTIS than with CORAIL (58.7% vs 35.3%). In logistic regression, proximal CFR significantly predicted spot-weld formation for ACTIS, with an optimal cutoff of 66.2% (sensitivity 91.9%, specificity 72.0%). Rates of subsidence, radiolucent lines, and pedestal formation did not differ significantly between groups. No severe stress shielding was observed with ACTIS, whereas three CORAIL hips demonstrated severe stress shielding (0% vs 5.9%). Clinical scores improved significantly in both groups, with no significant between-group differences at final follow-up.

Conclusions

Both stems yielded favorable radiographic and clinical mid-term outcomes. In ACTIS, greater proximal canal fill was associated with radiographic osseointegration, suggesting proximal CFR as a probabilistic radiographic marker of stem ingrowth.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Hip ProsthesisArthroplasty, Replacement, HipProsthesis DesignHumansRetrospective StudiesFemaleMaleRadiographyAgedMiddle AgedFollow-Up StudiesTreatment OutcomeTitanium

Stichwörter der Autor:innen

ACTISCORAILmid-term outcomeretrospective studytotal hip arthroplasty

Substanzen

Titanium

Autor:innen und Institutionen

  • Department of Orthopaedic Surgery, Section of Medicine, Division of Medicine, Dentistry and Pharmaceutical Sciences, Graduate School of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, Japan.
  • Department of Musculoskeletal Health Promotion, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, Japan.
  • Department of Orthopaedic Surgery, Okayama City General Medical Center, Okayama City Hospital, Okayama, Japan.
  • Department of Orthopaedic Surgery, Okayama University Hospital, Okayama, Japan.
  • Department of Sports Medicine, Faculty of Medicine, Dentistry and Pharmaceutical Sciences, Okayama University, Okayama, Japan.
  • Center for Education in Medicine and Health Sciences, Okayama University, Okayama, Japan.

ORCID-Profile: Tomonori Tetsunaga, Yuki Okazaki

Zitieren

APA

Masada, Y., Tetsunaga, T., Fujiwara, K., Yamada, K., Inoue, T., Okuda, R., Tetsunaga, T., Okazaki, Y., & Ozaki, T. (2026). Similar functional outcomes but different remodeling patterns: A minimum 5-years radiographic comparison of short fit-and-fill stem and quadrangular taper stem. Journal of Orthopaedic Surgery. https://doi.org/10.1177/10225536261434671

Vancouver

Masada Y, Tetsunaga T, Fujiwara K, Yamada K, Inoue T, Okuda R, et al. Similar functional outcomes but different remodeling patterns: A minimum 5-years radiographic comparison of short fit-and-fill stem and quadrangular taper stem. Journal of Orthopaedic Surgery. 2026. doi:10.1177/10225536261434671

BibTeX
@article{Masada2026,
  author = {Masada, Yasutaka and Tetsunaga, Tomonori and Fujiwara, Kazuo and Yamada, Kazuki and Inoue, Tomohiro and Okuda, Ryuichiro and Tetsunaga, Tomoko and Okazaki, Yuki and Ozaki, Toshifumi},
  title = {Similar functional outcomes but different remodeling patterns: A minimum 5-years radiographic comparison of short fit-and-fill stem and quadrangular taper stem},
  journal = {Journal of Orthopaedic Surgery},
  year = {2026},
  doi = {10.1177/10225536261434671}
}
Kostenlos starten →