EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Finite element analysis of the effect of tibial osteotomy on the stress of polyethylene liner in total knee arthroplasty

Lihui Sun iD, Yu Han, Zheng Jing iD, Dongbo Li, Jianguo Liu, Dongsong Li iD

Journal of Orthopaedic Surgery · 2024

DOI: 10.1177/10225536241251926 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Orthopaedic Surgery, 2024. Verfasst von Lihui Sun und 5 weiteren Autor:innen. Beteiligte Einrichtung: Division of Bone and Joint Surgery, Center of Orthopedics, First Hospital of Jilin University, Changchun, P. R. China. Hauptthemen laut MEDLINE: Finite Element Analysis, Arthroplasty, Replacement, Knee, Osteotomy, Polyethylene. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Jilin Province Development and Reform Commission.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aim

To explore the effects of tibial osteotomy varus angle combined with posterior tibial slope (PTS) on the stress of polyethylene liner in total knee arthroplasty (TKA) by building finite element model (FEM).

Methods

Established the FEM of standard TKA with tibial osteotomy varus angle 0° to 9° were established and divided into 10 groups. Next, each group was created 10 FEMs with 0° to 9° PTS separately. Calculated the stress on polyethylene liner in each group in Abaqus. Finally, the relevancy between tibial osteotomy angle and polyethylene liner stress was statistically analyzed using multiple regression analysis.

Results

As the varus angle increased, the area of maximum stress gradually shifted medially on the polyethylene liner. As the PTS increases, the percentage of surface contact forces on the medial and lateral compartmental of the polyethylene liner gradually converge to the same. When the varus angle is between 0° and 3°, the maximum stress of the medial compartmental surfaces of polyethylene liner rises smoothly with the increase of the PTS. When the varus angle is between 4° and 9°, as the increase of the PTS, the maximum stress of polyethylene liner rises first and then falls, forming a trough at PTS 5° and then rises again. Compared to the PTS, the varus angle has a large effect on the maximum stress of the polyethylene liner ( p < .001).

Conclusion

When the varus angle is 0° to 3°, PTS 0° is recommended, which will result in a more equalized stress distribution of the polyethylene liner in TKA.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Finite Element AnalysisArthroplasty, Replacement, KneeOsteotomyPolyethyleneTibiaStress, MechanicalKnee ProsthesisHumansProsthesis Design

Stichwörter der Autor:innen

finite element analysispolyethylene linerstresstibial osteotomy angletotal knee arthroplasty

Substanzen

Polyethylene

Autor:innen und Institutionen

  • Division of Bone and Joint Surgery, Center of Orthopedics, First Hospital of Jilin University, Changchun, P. R. China.

ORCID-Profile: Lihui Sun, Zheng Jing, Dongsong Li

Förderung

  • Jilin Province Development and Reform Commission

Zitieren

APA

Sun, L., Han, Y., Jing, Z., Li, D., Liu, J., & Li, D. (2024). Finite element analysis of the effect of tibial osteotomy on the stress of polyethylene liner in total knee arthroplasty. Journal of Orthopaedic Surgery. https://doi.org/10.1177/10225536241251926

Vancouver

Sun L, Han Y, Jing Z, Li D, Liu J, Li D. Finite element analysis of the effect of tibial osteotomy on the stress of polyethylene liner in total knee arthroplasty. Journal of Orthopaedic Surgery. 2024. doi:10.1177/10225536241251926

BibTeX
@article{Sun2024,
  author = {Sun, Lihui and Han, Yu and Jing, Zheng and Li, Dongbo and Liu, Jianguo and Li, Dongsong},
  title = {Finite element analysis of the effect of tibial osteotomy on the stress of polyethylene liner in total knee arthroplasty},
  journal = {Journal of Orthopaedic Surgery},
  year = {2024},
  doi = {10.1177/10225536241251926}
}
Kostenlos starten →