EUVIMEDEUVIMED entdecken
Crossref

Effect of substrate temperature on mechanical and electrochemical properties of flame-sprayed coatings for Titanium implants

Trong-Linh Nguyen iD, Tsung-Chieh Cheng

Bio-Medical Materials and Engineering · 2026

DOI: 10.1177/09592989261476170 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bio-Medical Materials and Engineering, 2026. Verfasst von Trong-Linh Nguyen und 1 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Mechanical Engineering, Hung Yen University of Technology and Education, Hung Yen, Vietnam. Hauptthemen laut MEDLINE: Titanium, Coated Materials, Biocompatible, Durapatite, Prostheses and Implants. Die Arbeit nennt 42 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Hydroxyapatite (HA) coatings on titanium (Ti) implants are widely studied owing to their biocompatibility and osteoconductivity. However, the effect of substrate temperature during flame spraying on coating performance remains unclear.

Objective

This study investigated the influence of substrate temperature on the microstructure, mechanical properties, and electrochemical behavior of flame-sprayed HA coatings on Ti implants.

Methods

HA coatings were deposited on commercially pure Ti Grade 2 substrates by flame spraying at room temperature (RT) and 300 °C. The coatings were characterized by XRD, FTIR, XPS, SEM, and EDS. Surface roughness, adhesion strength, abrasion resistance, potentiodynamic polarization, and electrochemical impedance spectroscopy were evaluated.

Results

Substrate heating at 300 °C modified the crystalline phase composition and slightly increased the apparent HA crystallite size and crystalline peak index. The 300 °C coating exhibited a more compact surface morphology, higher adhesion strength, lower abrasion-induced mass loss, lower corrosion current density, and higher charge transfer resistance than the RT coating.

Conclusion

Substrate heating at 300 °C improved the mechanical durability and corrosion resistance of flame-sprayed HA coatings, indicating its usefulness for enhancing Ti implant coating performance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

TitaniumCoated Materials, BiocompatibleDurapatiteProstheses and ImplantsSurface PropertiesMaterials TestingCorrosionTemperatureHot Temperature

Stichwörter der Autor:innen

Flame-sprayed hydroxyapatitecorrosion resistancemechanical propertiessubstrate temperaturetitanium implants

Substanzen

TitaniumCoated Materials, BiocompatibleDurapatite

Autor:innen und Institutionen

  • Faculty of Mechanical Engineering, Hung Yen University of Technology and Education, Hung Yen, Vietnam.
  • Department of Mechanical Engineering, National Kaohsiung University of Sciences and Technology, Kaohsiung, Taiwan.

ORCID-Profile: Trong-Linh Nguyen

Zitieren

APA

Nguyen, T. L., & Cheng, T. C. (2026). Effect of substrate temperature on mechanical and electrochemical properties of flame-sprayed coatings for Titanium implants. Bio-Medical Materials and Engineering. https://doi.org/10.1177/09592989261476170

Vancouver

Nguyen TL, Cheng TC. Effect of substrate temperature on mechanical and electrochemical properties of flame-sprayed coatings for Titanium implants. Bio-Medical Materials and Engineering. 2026. doi:10.1177/09592989261476170

BibTeX
@article{Nguyen2026,
  author = {Nguyen, Trong-Linh and Cheng, Tsung-Chieh},
  title = {Effect of substrate temperature on mechanical and electrochemical properties of flame-sprayed coatings for Titanium implants},
  journal = {Bio-Medical Materials and Engineering},
  year = {2026},
  doi = {10.1177/09592989261476170}
}
Kostenlos starten →