EUVIMEDEUVIMED entdecken
Crossref

Finite element analysis of six distinct fixation devices for vertically oriented femoral neck fractures

Yen-Nien Chen, Hsin-Chuan Chen, Chang-Han Chuang, Chih-Wei Chang, Yu-Hsuan Chung

Bio-Medical Materials and Engineering · 2026

DOI: 10.1177/09592989251414222 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bio-Medical Materials and Engineering, 2026. Verfasst von Yen-Nien Chen und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Physical Therapy, Asia university, Taichung, Taiwan. Hauptthemen laut MEDLINE: Femoral Neck Fractures, Fracture Fixation, Internal. Die Arbeit nennt 44 Literaturangaben. Gefördert von: Show Chwan Memorial Hospital.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Vertically oriented femoral neck fractures are a challenge for orthopedic surgeons, and the complication rates are also high. Recently, several innovative devices have been proposed, such as the proximal femoral bionic nail, InterTAN, and medial buttress plate combined with cannulated screws, to increase the stability of fixation. However, the differences among these innovative devices need to be addressed.

Objective

This study aimed to compare the stability of the proximal femoral bionic nail, InterTAN, and medial buttress plate combined with cannulated screws for vertically oriented femoral neck fractures. Additionally, traditional fixation devices—including three parallel cannulated screws, a compression hip screw system, and a proximal femoral nail—were included for comparison, resulting in a total of six distinct devices evaluated in this study.

Methods

A finite element model of a femoral neck fracture fixed with the six internal fixation devices was created. Furthermore, two different fracture conditions—with and without a 1-mm fracture gap—were considered. The maximum loading during level walking was applied to the model for comparison.

Results

The results indicated that the InterTAN has the best ability to maintain the gap and prevent collapse. Under the fracture gap condition, the peak displacement of the femoral head was smaller in the innovative devices compared to the traditional ones. Specifically, the peak displacements were 1.98 mm for the medial buttress plate combined with cannulated screws, 2.12 mm for the proximal femoral bionic nail, and 1.16 mm for the InterTAN system. The von Mises stress in the medial buttress plate was also the highest among the devices, with values of 1000 MPa with the gap and 1477 MPa without the gap.

Conclusion

Based on the present results, the medial buttress plate combined with cannulated screws, proximal femoral bionic nail, and InterTAN are recommended for cases without a fracture gap, while the InterTAN is recommended for cases with a fracture gap to prevent bone shortening.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Femoral Neck FracturesFracture Fixation, InternalFinite Element AnalysisHumansBone PlatesBone ScrewsBone NailsStress, MechanicalProximal Femoral Fractures

Stichwörter der Autor:innen

finite element analysismedial buttress plateproximal femoral InterTANproximal femoral bionic nailvertically oriented femoral neck fractures

Autor:innen und Institutionen

  • Department of Physical Therapy, Asia university, Taichung, Taiwan.
  • Department of Orthopedics, Show Chwan Memorial Hospital, Changhua, Taiwan.
  • Department of Orthopedics, Kaohsiung Show Chwan Memorial Hospital, Kaohsiung, Taiwan.
  • Department of Orthopedics, College of Medicine, National Cheng Kung University, Tainan, Taiwan.
  • Department of Orthopedics, National Cheng Kung University Hospital, College of Medicine, National Cheng Kung University, Tainan, Taiwan.
  • Translation Medicine, College of Life Sciences, National Chung-Hsing University, Tai-chung, Taiwan.

Förderung

  • Show Chwan Memorial Hospital

Zitieren

APA

Chen, Y. N., Chen, H. C., Chuang, C. H., Chang, C. W., & Chung, Y. H. (2026). Finite element analysis of six distinct fixation devices for vertically oriented femoral neck fractures. Bio-Medical Materials and Engineering. https://doi.org/10.1177/09592989251414222

Vancouver

Chen YN, Chen HC, Chuang CH, Chang CW, Chung YH. Finite element analysis of six distinct fixation devices for vertically oriented femoral neck fractures. Bio-Medical Materials and Engineering. 2026. doi:10.1177/09592989251414222

BibTeX
@article{Chen2026,
  author = {Chen, Yen-Nien and Chen, Hsin-Chuan and Chuang, Chang-Han and Chang, Chih-Wei and Chung, Yu-Hsuan},
  title = {Finite element analysis of six distinct fixation devices for vertically oriented femoral neck fractures},
  journal = {Bio-Medical Materials and Engineering},
  year = {2026},
  doi = {10.1177/09592989251414222}
}
Kostenlos starten →