EUVIMEDEUVIMED entdecken
Crossref

Transient multi-phase flow and pressure-response characteristics in a high-speed arc–involute–arc composite helical gear pump

Xuehui Chen, Lizhi Jiang, Ting Gao, Hewang Ma, Hao Li, Junpeng Zhang, Tao Ma, Jun Liang, Wei Liu

Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering · 21.11.2026

DOI: 10.1177/09544089261509315 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering, online erschienen am 21.11.2026. Verfasst von Xuehui Chen und 8 weiteren Autor:innen. Die Arbeit nennt 26 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study integrates analytical modeling, transient multi-phase computational fluid dynamics (CFD), and experiments to investigate the delivery and pressure-response characteristics of a high-speed arc–involute–arc composite helical gear pump. A coordinate- and tangent-continuous tooth profile and an analytical instantaneous-flow model incorporating axial phase differences provide a geometric displacement reference. A three-dimensional transient multi-phase CFD model is established in Simerics-MP+ using oil properties prescribed at 318 K. The combined approach assesses departures from geometric flow predictions. As rotational speed increases from 4000 to 5500 r/min, the CFD-predicted flow pulsation rate increases from 26.48% to 36.98%, while volumetric efficiency decreases from 95.17% to 91.10%. Numerical flow fields associate these changes with insufficient suction filling, clearance reverse flow, and local gas–vapor evolution. At 5000 r/min, increasing load pressure from 0.5 to 6.5 MPa reduces the predicted relative pressure pulsation rate from 12.96% to 1.65%. However, the absolute peak-to-peak pressure fluctuation remains within 0.065–0.110 MPa, indicating that the relative reduction primarily reflects increasing mean pressure. Experiments reproduce the speed- and load-dependent trends, with the maximum relative volumetric-efficiency deviations of 3.94% and 2.53%, respectively. The maximum relative deviation in the flow pulsation rate is 6.83% at 5000 r/min. Relative pressure pulsation is consistently underpredicted by 0.85–2.56 percentage points. These findings provide a geometry-specific basis for evaluating delivery efficiency and pulsation.

Zitieren

APA

Chen, X., Jiang, L., Gao, T., Ma, H., Li, H., Zhang, J., Ma, T., Liang, J., & Liu, W. (2026). Transient multi-phase flow and pressure-response characteristics in a high-speed arc–involute–arc composite helical gear pump. Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering. https://doi.org/10.1177/09544089261509315

Vancouver

Chen X, Jiang L, Gao T, Ma H, Li H, Zhang J, et al. Transient multi-phase flow and pressure-response characteristics in a high-speed arc–involute–arc composite helical gear pump. Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering. 2026. doi:10.1177/09544089261509315

BibTeX
@article{Chen2026,
  author = {Chen, Xuehui and Jiang, Lizhi and Gao, Ting and Ma, Hewang and Li, Hao and Zhang, Junpeng and Ma, Tao and Liang, Jun and Liu, Wei},
  title = {Transient multi-phase flow and pressure-response characteristics in a high-speed arc–involute–arc composite helical gear pump},
  journal = {Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering},
  year = {2026},
  doi = {10.1177/09544089261509315}
}
Kostenlos starten →