Flow characteristics and factors affecting flow pulsation of external meshing herringbone gear pump

Jinlong Yang, Chul-Hee Lee

Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering · 2026-06 · 240 (3) · 2589-2600

DOI: 10.1177/09544089241281158 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering, online erschienen am 23.09.2024. Verfasst von Jinlong Yang und 1 weiteren Autor:innen. Die Arbeit nennt 36 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

To enhance the outlet flow stability of the external herringbone gear pump, an analysis was conducted on the main influencing factors, key geometric parameters were identified, and a numerical model was developed for fluid analysis. A numerical model was then established for fluid analysis. The accuracy of the numerical model was verified by comparing it with experimental results, with simulation errors of displacement and volumetric efficiency being < 5%, ensuring the simulation's accuracy. The simulation results indicated that the pump's head (49.7808 m) and outlet pressure (4.9285 bar) remained stable. At 700 rev/min, the simulated volumetric efficiency was 82.94%. Subsequently, the impact of helix angle, changes in center distance, and tip clearance on outlet flow stability were analyzed. The analysis revealed that increasing the helix angle from 27° to 30° could reduce flow pulsation. A slight reduction in center distance from 180.3 (δ = +0.3 mm) to 179.9 mm (δ = −0.1 mm) effectively decreased mass flow difference and outlet pressure pulsation, enhancing outlet output stability. Reducing tip clearance from 0.25 to 0.12 mm, while meeting design requirements, resulted in more stable pressure and lift output. These results ensured smooth pump operation, improved outlet output stability, and met low-flow pulsation requirements. This study offered valuable insights into the design and production of the external meshing herringbone gear pump.

Zitieren

APA

Yang, J., & Lee, C. (2026). Flow characteristics and factors affecting flow pulsation of external meshing herringbone gear pump. Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering, 240(3), 2589-2600. https://doi.org/10.1177/09544089241281158

Vancouver

Yang J, Lee C. Flow characteristics and factors affecting flow pulsation of external meshing herringbone gear pump. Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering. 2026;240(3):2589-2600. doi:10.1177/09544089241281158

BibTeX
@article{Yang2026,
  author = {Yang, Jinlong and Lee, Chul-Hee},
  title = {Flow characteristics and factors affecting flow pulsation of external meshing herringbone gear pump},
  journal = {Proceedings of the Institution of Mechanical Engineers, Part E: Journal of Process Mechanical Engineering},
  year = {2026},
  volume = {240},
  number = {3},
  pages = {2589--2600},
  doi = {10.1177/09544089241281158}
}