DBT reconstruction based on 3D coordinate transformation of multi-angle projections
Journal of X-Ray Science and Technology · 2026
DOI: 10.1177/08953996261469039 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology, 2026. Verfasst von Ping Chen und 1 weiteren Autor:innen. Beteiligte Einrichtung: Nanjing University of Posts and Telecommunications, College of Electronic and Optical Engineering & College of Flexible Electronics (Future Technolog…. Hauptthemen laut MEDLINE: Imaging, Three-Dimensional, Mammography. Die Arbeit nennt 34 Literaturangaben. Gefördert von: Jiangsu Natural Science Foundation, Natural Science Research Program of Jiangsu Higher Education Institutions, Jiangsu Provincial Key Laboratory of Advanced Catalytic Materials and Technology Department, Jiangsu Provincial Department of Science and Technology.
Abstract (Originalsprache)
Purpose
Digital Breast Tomosynthesis (DBT) is an emerging imaging technique for diagnosing breast disease. It reconstructs three-dimensional (3D) tomographic images from a limited number of projections within a restricted angular range. This technique effectively reduces tissue overlap and improves lesion detection rates. However, conventional reconstruction relies on a paraxial approximation, neglecting the increasing vertical geometric distortion at the detector periphery. This, distortion, blurring the microcalcifications and subtle lesions, is to be decreased by a proposed reconstruction. Approach The proposed reconstruction uses 3D coordinate transformation to overcome the geometric distortion and so it follows a sequential five-step pipeline: preprocessing, coordinate transformation, interpolation, weighting, and reconstructing. First, multi-angle projections undergo the preprocessing of background segmentation and filtering. Second, a 3D coordinate transformation is applied to each projection based on its acquisition angle and depth. Then, linear interpolation is used to fill data gaps caused by the spatial shift. Next, an angular weighting scheme balances the sampling density from different projections. Finally, tomographic images are reconstructed from these processed projections.
Results
Experimental results show that the 3D coordinate transformation improves geometric accuracy and reduces distortion. Specifically, for FBP reconstruction, the proposed method increased Peak Signal-to-Noise Ratio (PSNR) by 1.19 dB and reduced Standard Deviation (SD) by 403.53. For MLEM reconstruction, the Contrast-to-Noise Ratio (CNR) is improved by approximately 15.4%. Clinical data further confirm that these quantitative improvements help in differentiating lesions from the surrounding background.
Conclusions
The proposed DBT reconstruction based on 3D coordinate transformation improves image quality, showing potential for broader clinical applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Nanjing University of Posts and Telecommunications, College of Electronic and Optical Engineering & College of Flexible Electronics (Future Technology), Nanjing 210023, China.
ORCID-Profile: Chunyu Yu
Förderung
- Jiangsu Natural Science Foundation
- Natural Science Research Program of Jiangsu Higher Education Institutions
- Jiangsu Provincial Key Laboratory of Advanced Catalytic Materials and Technology Department, Jiangsu Provincial Department of Science and Technology
- Doctoral Program Foundation of Institutions of Higher Education of China
Zitieren
APA
Chen, P., & Yu, C. (2026). DBT reconstruction based on 3D coordinate transformation of multi-angle projections. Journal of X-Ray Science and Technology. https://doi.org/10.1177/08953996261469039
Vancouver
Chen P, Yu C. DBT reconstruction based on 3D coordinate transformation of multi-angle projections. Journal of X-Ray Science and Technology. 2026. doi:10.1177/08953996261469039
BibTeX
@article{Chen2026,
author = {Chen, Ping and Yu, Chunyu},
title = {DBT reconstruction based on 3D coordinate transformation of multi-angle projections},
journal = {Journal of X-Ray Science and Technology},
year = {2026},
doi = {10.1177/08953996261469039}
}
EUVIMED