Projection-domain reconstruction of patient-specific panoramic images from CBCT projection data
Journal of X-Ray Science and Technology · 2026-07 · 34 (4) · 569-585
DOI: 10.1177/08953996261444397 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology, online erschienen am 29.05.2026. Verfasst von Jiyong Shim und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiation Convergence Engineering, Yonsei University, Wonju, Republic of Korea. Hauptthemen laut MEDLINE: Cone-Beam Computed Tomography, Radiography, Panoramic, Image Processing, Computer-Assisted. Die Arbeit nennt 29 Literaturangaben. Gefördert von: Korea Medical Device Development Fund.
Abstract (Originalsprache)
Background
Panoramic radiography is widely used in dental diagnostics; however, conventional systems require a dedicated panoramic scan, increasing radiation exposure and limiting adaptation to patient-specific anatomical variability. Cone-beam computed tomography (CBCT) provides volumetric information that may potentially replace separate panoramic acquisitions.
Purpose
This study proposes CT2Pano, a projection-domain reconstruction method that generates patient-specific panoramic images directly from CBCT projection data without requiring an additional panoramic scan.
Methods
The CT2Pano algorithm automatically detects teeth from CBCT images and estimates a patient-specific dental arch curve using Bézier curve optimization. Based on the extracted arch, a virtual panoramic scan trajectory is defined and panoramic projections are extracted from the corresponding CBCT projections. Geometric correction combined with subpixel rebinning compensates for magnification variations caused by the fixed rotation center of the CBCT systems. The final panoramic image is reconstructed using a shift-and-add (SAA) method that enhances structures within the focal trough while suppressing out-of-plane structures.
Results
Simulation and phantom experiments demonstrate that CT2Pano generates panoramic images with anatomical fidelity comparable to conventional panoramic imaging systems. The method effectively compensates for geometric distortion and maintains image quality even in the presence of metal artifacts or patient misalignment.
Conclusions
CT2Pano enables patient-specific panoramic reconstruction directly from CBCT projection data, eliminating the need for an additional panoramic scan. By operating in the projection domain, the proposed framework preserves measurement information while reducing radiation exposure and improving imaging workflow efficiency, highlighting its potential for CBCT-based panoramic imaging in dental diagnostics.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiation Convergence Engineering, Yonsei University, Wonju, Republic of Korea.
Förderung
- Korea Medical Device Development Fund
Zitieren
APA
Shim, J., Yang, H., & Cho, H. (2026). Projection-domain reconstruction of patient-specific panoramic images from CBCT projection data. Journal of X-Ray Science and Technology, 34(4), 569-585. https://doi.org/10.1177/08953996261444397
Vancouver
Shim J, Yang H, Cho H. Projection-domain reconstruction of patient-specific panoramic images from CBCT projection data. Journal of X-Ray Science and Technology. 2026;34(4):569-585. doi:10.1177/08953996261444397
BibTeX
@article{Shim2026,
author = {Shim, Jiyong and Yang, Hyesun and Cho, Hyosung},
title = {Projection-domain reconstruction of patient-specific panoramic images from CBCT projection data},
journal = {Journal of X-Ray Science and Technology},
year = {2026},
volume = {34},
number = {4},
pages = {569--585},
doi = {10.1177/08953996261444397}
}