Low-dose CT reconstruction network based on the unfoldment of second-order TGV
Journal of X-Ray Science and Technology · 2026-05 · 34 (3) · 356-370
DOI: 10.1177/08953996261440879 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology, online erschienen am 09.04.2026. Verfasst von Hangqi Wu und 6 weiteren Autor:innen. Beteiligte Einrichtung: State key Laboratory of Extreme Environment Optoelectronic Dynamic Testing Technology and Instrument, North University of China, Taiyuan, China. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Image Processing, Computer-Assisted. Die Arbeit nennt 44 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Natural Science Foundation of Shanxi Province, Research Project Supported by Shanxi Scholarship Council of China.
Abstract (Originalsprache)
Background
Total generalized variation (TGV) based CT iterative reconstruction algorithm has the ability to effectively suppress the staircase effects caused by the piecewise constant assumption of total variation regularization. By unrolling the model-based iterative reconstruction to networks, the deep unrolling approach can further improve image quality within a finite number of iterations by data-driven training. However, most deep unrolling approaches focus on unrolling the data fidelity term into deep neural networks, which limit the performance of the deep unrolling approach.
Objective
To address this issue, we unrolled both the data fidelity term and the TGV term to construct a novel low-dose CT reconstruction network, called TGV based deep unrolling approach (TGV-DU).
Methods
The Chambolle-Pock algorithm was employed to solve the TGV based CT iterative reconstruction problem to obtain a single-loop CT iterative reconstruction algorithm, which is easy to be unrolled to neural networks. In the proposed algorithm, the parameterized mapping that updates primal variables and dual variables across successive iterations was implemented by convolutional neural networks and was dynamically learned from big data.
Results
To validate the effectiveness of our proposed algorithm, we perform the experiment on the “Low-Does CT Image and Projection Data” dataset. The results show that the proposed TGV-DU outperforms other state-of-the-art methods quantitatively and qualitatively.
Conclusions
Experiments show that our proposed algorithm can effectively alleviate the piecewise smoothness while preserve more structural details.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- State key Laboratory of Extreme Environment Optoelectronic Dynamic Testing Technology and Instrument, North University of China, Taiyuan, China.
- School of Information and Communication Engineering, North University of China, Taiyuan, China.
- School of Software, North University of China, Taiyuan, China.
ORCID-Profile: Zhiguo Gui
Förderung
- National Natural Science Foundation of China
- Natural Science Foundation of Shanxi Province
- Research Project Supported by Shanxi Scholarship Council of China
- Innovation Project for Graduate Student of Shanxi Province
Zitieren
APA
Wu, H., Zhang, P., Li, S., Lu, J., Liu, Y., Kang, J., & Gui, Z. (2026). Low-dose CT reconstruction network based on the unfoldment of second-order TGV. Journal of X-Ray Science and Technology, 34(3), 356-370. https://doi.org/10.1177/08953996261440879
Vancouver
Wu H, Zhang P, Li S, Lu J, Liu Y, Kang J, et al. Low-dose CT reconstruction network based on the unfoldment of second-order TGV. Journal of X-Ray Science and Technology. 2026;34(3):356-370. doi:10.1177/08953996261440879
BibTeX
@article{Wu2026,
author = {Wu, Hangqi and Zhang, Pengcheng and Li, Shu and Lu, Jing and Liu, Yi and Kang, Jiaqi and Gui, Zhiguo},
title = {Low-dose CT reconstruction network based on the unfoldment of second-order TGV},
journal = {Journal of X-Ray Science and Technology},
year = {2026},
volume = {34},
number = {3},
pages = {356--370},
doi = {10.1177/08953996261440879}
}
EUVIMED