EUVIMEDEUVIMED entdecken
Crossref

Performance evaluation of deep learning image reconstruction algorithm for dual-energy spectral CT imaging: A phantom study

Haoyan Li, Zhentao Li, Shuaiyi Gao, Jiaqi Hu, Zhihao Yang, Yun Peng, Jihang Sun

Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics · 2024

DOI: 10.3233/xst-230333 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics, 2024. Verfasst von Haoyan Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China. Hauptthemen laut MEDLINE: Phantoms, Imaging, Deep Learning, Tomography, X-Ray Computed, Algorithms. Die Arbeit nennt 36 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

OBJECTIVES: To evaluate the performance of deep learning image reconstruction (DLIR) algorithm in dual-energy spectral CT (DEsCT) as a function of radiation dose and image energy level, in comparison with filtered-back-projection (FBP) and adaptive statistical iterative reconstruction-V (ASIR-V) algorithms. METHODS: An ACR464 phantom was scanned with DEsCT at four dose levels (3.5 mGy, 5 mGy, 7.5 mGy, and 10 mGy). Virtual monochromatic images were reconstructed at five energy levels (40 keV, 50 keV, 68 keV, 74 keV, and 140 keV) using FBP, 50% and 100% ASIR-V, DLIR at low (DLIR-L), medium (DLIR-M), and high (DLIR-H) settings. The noise power spectrum (NPS), task-based transfer function (TTF) and detectability index (d’) were computed and compared among reconstructions. RESULTS: NPS area and noise increased as keV decreased, with DLIR having slower increase than FBP and ASIR-V, and DLIR-H having the lowest values. DLIR had the best 40 keV/140 keV noise ratio at various energy levels, DLIR showed higher TTF (50%) than ASIR-V for all materials, especially for the soft tissue-like polystyrene insert, and DLIR-M and DLIR-H provided higher d’ than DLIR-L, ASIR-V and FBP in all dose and energy levels. As keV increases, d’ increased for acrylic insert, and d’ of the 50 keV DLIR-M and DLIR-H images at 3.5 mGy (7.39 and 8.79, respectively) were higher than that (7.20) of the 50 keV ASIR-V50% images at 10 mGy. CONCLUSIONS: DLIR provides better noise containment for low keV images in DEsCT and higher TTF(50%) for the polystyrene insert over ASIR-V. DLIR-H has the lowest image noise and highest detectability in all dose and energy levels. DEsCT 50 keV images with DLIR-M and DLIR-H show potential for 65% dose reduction over ASIR-V50% withhigher d’.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Phantoms, ImagingDeep LearningTomography, X-Ray ComputedAlgorithmsImage Processing, Computer-AssistedRadiation DosageSignal-To-Noise RatioRadiography, Dual-Energy Scanned ProjectionHumans

Stichwörter der Autor:innen

Multidetector computed tomographydeep learningimage enhancementimage reconstruction

Autor:innen und Institutionen

  • Department of Radiology, Beijing Children's Hospital, Capital Medical University, National Center for Children's Health, Beijing, China.
  • Department of Radiology, Peking University People's Hospital, Beijing, China.

Zitieren

APA

Li, H., Li, Z., Gao, S., Hu, J., Yang, Z., Peng, Y., & Sun, J. (2024). Performance evaluation of deep learning image reconstruction algorithm for dual-energy spectral CT imaging: A phantom study. Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics. https://doi.org/10.3233/xst-230333

Vancouver

Li H, Li Z, Gao S, Hu J, Yang Z, Peng Y, et al. Performance evaluation of deep learning image reconstruction algorithm for dual-energy spectral CT imaging: A phantom study. Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics. 2024. doi:10.3233/xst-230333

BibTeX
@article{Li2024,
  author = {Li, Haoyan and Li, Zhentao and Gao, Shuaiyi and Hu, Jiaqi and Yang, Zhihao and Peng, Yun and Sun, Jihang},
  title = {Performance evaluation of deep learning image reconstruction algorithm for dual-energy spectral CT imaging: A phantom study},
  journal = {Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics},
  year = {2024},
  doi = {10.3233/xst-230333}
}
Kostenlos starten →