EUVIMEDEUVIMED entdecken
Crossref

Single-Mask edge illumination X-ray multimodal imaging: Methodology and parameter impact mechanisms

Chang Li, Liangliang Lv, Zhi Zhou, Yinqi Lei, Xiaodong Pan, Cui Zhang, Gongping Li

Journal of X-Ray Science and Technology · 2026

DOI: 10.1177/08953996261421455 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology, 2026. Verfasst von Chang Li und 6 weiteren Autor:innen. Beteiligte Einrichtung: Frontiers Science Center for Rare Isotopes, Lanzhou University, Lanzhou, 730000, China. Hauptthemen laut MEDLINE: Multimodal Imaging, Image Processing, Computer-Assisted, Lighting. Die Arbeit nennt 45 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Fundamental Research Funds for the Central Universities.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

X-ray multimodal imaging, which extracts absorption, refraction, and scattering signals simultaneously, holds significant potential in biomedical and materials science applications. However, laboratory-based X-ray multimodal imaging remains underdeveloped, with existing techniques constrained by system magnification and detector pixel size. This study employs a single-mask edge illumination (SM EI) configuration and establishes the corresponding single-mask illumination curve (SM IC). Using Geant4 simulations, we validate the feasibility of retrieving all three signals under conventional magnification and large-pixel detectors. Results show accurate extraction of both refraction and scattering signals, with model fitting close to unity. We further explore the impact of key system parameters, including focal spot size, tube voltage, mask thickness, duty cycle, pixel count, and detector operation mode on imaging performance. The simulations reveal that small focal spots and low-energy X-rays enhance contrast, thick masks maintain signal quality at high energy, and low duty cycles and high photon counts improve the contrast-to-noise ratio ( CNR ). Additionally, the charge summing mode increases refraction CNR by approximately three times compared to standard modes. These findings demonstrate the effectiveness of the SM EI method, enhancing spatial resolution and providing optimization insights for designing laboratory-based X-ray multimodal imaging systems.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Multimodal ImagingImage Processing, Computer-AssistedLightingSignal-To-Noise RatioComputer SimulationAlgorithmsPhantoms, ImagingX-Rays

Stichwörter der Autor:innen

Geant4 simulationX-ray multimodal imagingillumination curveparameter optimizationsingle-mask edge illumination

Autor:innen und Institutionen

  • Frontiers Science Center for Rare Isotopes, Lanzhou University, Lanzhou, 730000, China.
  • School of Nuclear Science and Technology, Lanzhou University, Lanzhou, 730000, China.
  • Institute of Chemical Materials, China Academy of Engineering Physics, Mianyang, 621999, China.

Förderung

  • National Natural Science Foundation of China
  • Fundamental Research Funds for the Central Universities

Zitieren

APA

Li, C., Lv, L., Zhou, Z., Lei, Y., Pan, X., Zhang, C., & Li, G. (2026). Single-Mask edge illumination X-ray multimodal imaging: Methodology and parameter impact mechanisms. Journal of X-Ray Science and Technology. https://doi.org/10.1177/08953996261421455

Vancouver

Li C, Lv L, Zhou Z, Lei Y, Pan X, Zhang C, et al. Single-Mask edge illumination X-ray multimodal imaging: Methodology and parameter impact mechanisms. Journal of X-Ray Science and Technology. 2026. doi:10.1177/08953996261421455

BibTeX
@article{Li2026,
  author = {Li, Chang and Lv, Liangliang and Zhou, Zhi and Lei, Yinqi and Pan, Xiaodong and Zhang, Cui and Li, Gongping},
  title = {Single-Mask edge illumination X-ray multimodal imaging: Methodology and parameter impact mechanisms},
  journal = {Journal of X-Ray Science and Technology},
  year = {2026},
  doi = {10.1177/08953996261421455}
}
Kostenlos starten →