Static CT imaging method based on multi-line array X-ray sources
Journal of X-Ray Science and Technology · 2026-05 · 34 (3) · 270-283
DOI: 10.1177/08953996261420977 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology, online erschienen am 02.04.2026. Verfasst von Hai Wang und 4 weiteren Autor:innen. Beteiligte Einrichtung: The School of Information Engineering, Nanchang University, Nanchang, China. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Image Processing, Computer-Assisted. Die Arbeit nennt 45 Literaturangaben. Gefördert von: WeiwenWu.
Abstract (Originalsprache)
Static computed tomography (CT) is an advanced 3D measurement technology. It offers key instrumentation advantages by reducing motion-induced artifacts, preserving measurement accuracy, and lowering radiation doses— critical factors for precision systems. This capability is particularly crucial for imaging moving organs such as the heart. This study introduces a novel Multi-Array Stationary CT (MASCT) imaging architecture. Utilizing cold- cathode carbon nanotube X-ray sources, the proposed architecture achieves dual innovations in temporal and spatial resolution, advancing stationary CT instrument design. Firstly, the X-ray source's rapid response allows for swift data acquisition. Coupled with its low power consumption and compact form factor, these characteristics collectively facilitate high temporal resolution, meeting the demands of dynamic imaging. Second, the densely arranged source array enhances angular resolution, while the z-axis MAS configuration extends scanning capacity for elongated objects, thereby expanding spatial resolution across multiple dimensions. To address practical implementation challenges, we incorporate iterative reconstruction algorithms to solve limited-angle problem, achieving diagnostically acceptable image quality. The feasibility of our multi-array X-ray source-based static CT system is rigorously validated through both numerical simulations and physical experiments.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- The School of Information Engineering, Nanchang University, Nanchang, China.
- The School of Biomedical Engineering, Sun Yat-sen University, Shenzhen, China.
Förderung
- WeiwenWu
Zitieren
APA
Wang, H., Wu, Y., Wang, S., Guo, Z., & Wu, W. (2026). Static CT imaging method based on multi-line array X-ray sources. Journal of X-Ray Science and Technology, 34(3), 270-283. https://doi.org/10.1177/08953996261420977
Vancouver
Wang H, Wu Y, Wang S, Guo Z, Wu W. Static CT imaging method based on multi-line array X-ray sources. Journal of X-Ray Science and Technology. 2026;34(3):270-283. doi:10.1177/08953996261420977
BibTeX
@article{Wang2026,
author = {Wang, Hai and Wu, Yanwen and Wang, Shaoyu and Guo, Zhijun and Wu, Weiwen},
title = {Static CT imaging method based on multi-line array X-ray sources},
journal = {Journal of X-Ray Science and Technology},
year = {2026},
volume = {34},
number = {3},
pages = {270--283},
doi = {10.1177/08953996261420977}
}
EUVIMED