EUVIMEDEUVIMED entdecken
Crossref

The usefulness of X-ray output management in general radiography systems using exposure index

Kazuhiro Ogasawara iD, Shinya Ohwada, Rie Tachibana, Katsuhiko Ogasawara iD

Journal of X-Ray Science and Technology · 2025

DOI: 10.1177/08953996241299994 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of X-Ray Science and Technology, 2025. Verfasst von Kazuhiro Ogasawara und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Diagnostic Imaging, Hokkaido Social Work Association Obihiro Hospital, Obihiro, Hokkaido, Japan. Hauptthemen laut MEDLINE: Radiography. Die Arbeit nennt 13 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The periodic quality control of X-ray devices is important for obtaining optical medical images and determining the appropriate X-ray exposure dose. Additionally, the measurement of the X-ray output is constrained by time, technical aspects, and expenses. Therefore, we investigated the usefulness of a simple method for managing X-ray output using an Exposure Index (EI).

Methods

The entire surface of the flat panel detector was X-ray-irradiated every Friday at the time of end-of-work inspection under the condition that the recorded EI was approximately 1000. The EI and exposure dose were measured, and the linearity and accuracy were evaluated.

Results

The output gradually decreased from the start of the measurements in Room 1 and stabilized after the output was adjusted. The relationship between exposure dose and EI showed high linearity, with R 2 > 0.99, and the CV of EI was less than 2.41%, indicating high reproducibility.

Conclusions

We demonstrated that the results of constancy tests can be easily quantified using EI. The EI method can manage the X-ray output with good reproducibility.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RadiographyRadiation DosageReproducibility of ResultsX-RaysHumansQuality Control

Stichwörter der Autor:innen

X-ray outputconstancy testsdigital radiographyexposure doseexposure indexflat panel detector

Autor:innen und Institutionen

  • Department of Diagnostic Imaging, Hokkaido Social Work Association Obihiro Hospital, Obihiro, Hokkaido, Japan.
  • Graduate School of Engineering, Muroran Institute of Technology, Muroran, Hokkaido, Japan.
  • Faculty of Health Sciences, Hokkaido University, Sapporo, Japan.

ORCID-Profile: Kazuhiro Ogasawara, Katsuhiko Ogasawara

Zitieren

APA

Ogasawara, K., Ohwada, S., Tachibana, R., & Ogasawara, K. (2025). The usefulness of X-ray output management in general radiography systems using exposure index. Journal of X-Ray Science and Technology. https://doi.org/10.1177/08953996241299994

Vancouver

Ogasawara K, Ohwada S, Tachibana R, Ogasawara K. The usefulness of X-ray output management in general radiography systems using exposure index. Journal of X-Ray Science and Technology. 2025. doi:10.1177/08953996241299994

BibTeX
@article{Ogasawara2025,
  author = {Ogasawara, Kazuhiro and Ohwada, Shinya and Tachibana, Rie and Ogasawara, Katsuhiko},
  title = {The usefulness of X-ray output management in general radiography systems using exposure index},
  journal = {Journal of X-Ray Science and Technology},
  year = {2025},
  doi = {10.1177/08953996241299994}
}
Kostenlos starten →