Comparison of typical radiation doses and risks using an anthropomorphic ‘bone fracture’ phantom for commonly performed X‐ray projections in a 5‐year‐old
Journal of Medical Radiation Sciences · 2024
DOI: 10.1002/jmrs.717 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Medical Radiation Sciences, 2024. Verfasst von Edel Doyle und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Forensic Medicine, Monash University, Melbourne, Victoria, Australia. Hauptthemen laut MEDLINE: Software. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Introduction
Diagnostic reference levels (DRLs) are typical dose levels for medical imaging examinations for groups of standard‐sized patients or standard phantoms for broadly defined types of equipment used as a tool to aid optimisation of protection for medical exposures. Currently, there are no paediatric DRLs for conventional radiography (i.e. general X‐rays) published in Australia. The aim of this study was to establish typical radiation doses and risks that are representative of those delivered for commonly performed X‐ray projections for a 5‐year‐old/20 kg child using a 5‐year‐old anthropomorphic ‘bone fracture’ phantom in three dedicated paediatric radiology departments in Victoria.
Methods
A total of 20 projection images were acquired for a standard 5‐year‐old/20 kg phantom using digital radiography X‐ray equipment. The air kerma‐area product (KAP) measured at each centre by a KAP metre, which was calibrated to a national primary standard, was considered to represent the median value for that centre for each X‐ray projection. Organ doses and effective dose were estimated using PCXMC software, and risks of radiation‐induced cancer and radiation‐induced death were calculated based on the BEIR VII report.
Results
The typical doses for the individual X‐ray projections ranged from 3 mGy•cm 2 to 86 mGy•cm 2 , whilst the effective doses ranged from 0.00004 to 0.07 mSv. The radiation risks were ‘minimal’ to ‘negligible’.
Conclusion
The estimation of typical radiation doses and associated risks for a 5‐year‐old/20 kg phantom study provides reference values for guidance and is a first step in assisting optimisation at other institutions until national DRLs, based on patient data from the clinical setting, are published.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Forensic Medicine, Monash University, Melbourne, Victoria, Australia.
- Department of Medical Imaging and Radiation Sciences, Monash University, Melbourne, Victoria, Australia.
- School of Allied Health Professions, Keele University, Keele, UK.
- Australian Radiation Protection and Nuclear Safety Agency, Yallambie, Victoria, Australia.
- Victorian Institute of Forensic Medicine, Academic Programs, Melbourne, Victoria, Australia.
ORCID-Profile: Edel Doyle, Matthew R Dimmock, Kam L Lee, Peter Thomas, Richard B Bassed
Zitieren
APA
Doyle, E., Dimmock, M. R., Lee, K. L., Thomas, P., & Bassed, R. B. (2024). Comparison of typical radiation doses and risks using an anthropomorphic ‘bone fracture’ phantom for commonly performed X‐ray projections in a 5‐year‐old. Journal of Medical Radiation Sciences. https://doi.org/10.1002/jmrs.717
Vancouver
Doyle E, Dimmock MR, Lee KL, Thomas P, Bassed RB. Comparison of typical radiation doses and risks using an anthropomorphic ‘bone fracture’ phantom for commonly performed X‐ray projections in a 5‐year‐old. Journal of Medical Radiation Sciences. 2024. doi:10.1002/jmrs.717