Effect of Matrix Size and Acquisition Mode on Image Quality and Radiation Dose of Ultra-High-Resolution CT of the Temporal Bone: An Anatomical Study

Ulysse Puel, Michael Eliezer, Fatma Boubaker, Nicolas Villani, Bouchra Assabah, Gabriela Hossu, Pedro Augusto Gondim Teixeira iD, Alain Blum iD, Cécile Parietti-Winkler, Romain Gillet

Canadian Association of Radiologists Journal · 2024

DOI: 10.1177/08465371241234795 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Canadian Association of Radiologists Journal, 2024. Verfasst von Ulysse Puel und 9 weiteren Autor:innen. Beteiligte Einrichtung: Guilloz Imaging Department, Central Hospital, University Hospital Center of Nancy, Nancy, France. Hauptthemen laut MEDLINE: Radiation Dosage, Temporal Bone, Cadaver, Signal-To-Noise Ratio. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 31 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare image quality and radiation exposure between super- and ultra-high-resolution helical and super-high-resolution volumetric CT of the temporal bone.

Methods

Six cadaveric temporal bone specimens were used to evaluate key temporal bone structures using the following CT reconstruction and acquisition modes: helical and single-volume acquisition modes in super-high resolution (0.25-mm slice thickness, 1024 2 matrix), and helical mode in ultra-high resolution (0.25-mm slice thickness, 2048 2 matrix). Two observers performed 5 previously described preoperative measurements, measured noise and signal-to-noise ratios for air, and noise for bone, and rated the visualization of 5 anatomical structures on a 4-point scale, for each reconstruction mode. Radiation dose exposure was recorded for each examination.

Results

There was no significant difference between any of the quantitative or qualitative measurements in any of the reconstruction and acquisition modes. There was a slight increase in noise and a decrease in signal-to-noise ratio in the air using the single-volume mode (115 ± 13.1 HU and 8.37 ± 0.91, respectively) compared to the helicoidal super-high-resolution (92.4 ± 11.8 HU and 10.8 ± 1.26, respectively) and helicoidal ultra-high-resolution (91.1 ± 10.7 HU and 10.9 ± 1.39, respectively) modes ( P < .002). The volumic CT dose index was 50.9 mGy with helical acquisition and 29.8 mGy with single-volume acquisition mode ( P < .0001).

Conclusion

The single-volume super-high-resolution acquisition mode allows a reduction in radiation dose exposure without compromising image quality compared to helical scanning, but with a slightly lower signal-to-noise ratio in air with the single-volume mode, while there was no difference in image quality between the helical super- and ultra-high-resolution modes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Radiation DosageTemporal BoneCadaverSignal-To-Noise RatioHumansTomography, Spiral ComputedRadiographic Image Interpretation, Computer-AssistedTomography, X-Ray Computed

Stichwörter der Autor:innen

CTimage qualityradiation dosetemporal boneultra-high-resolution

Autor:innen und Institutionen

  • Guilloz Imaging Department, Central Hospital, University Hospital Center of Nancy, Nancy, France.
  • Université de Lorraine, INSERM, IADI, Nancy, France.
  • Université de Lorraine, CIC, Innovation Technologique, University Hospital Center of Nancy, Nancy, France.
  • Department of Radiology, Lariboisière Hospital, Paris, France.
  • Department of Anatomy, Université de Lorraine, Nancy, France.
  • ENT Surgery Department, Central Hospital, University Hospital Center of Nancy, Nancy, France.

ORCID-Profile: Pedro Augusto Gondim Teixeira, Alain Blum

Zitieren

APA

Puel, U., Eliezer, M., Boubaker, F., Villani, N., Assabah, B., Hossu, G., Gondim Teixeira, P. A., Blum, A., Parietti-Winkler, C., & Gillet, R. (2024). Effect of Matrix Size and Acquisition Mode on Image Quality and Radiation Dose of Ultra-High-Resolution CT of the Temporal Bone: An Anatomical Study. Canadian Association of Radiologists Journal. https://doi.org/10.1177/08465371241234795

Vancouver

Puel U, Eliezer M, Boubaker F, Villani N, Assabah B, Hossu G, et al. Effect of Matrix Size and Acquisition Mode on Image Quality and Radiation Dose of Ultra-High-Resolution CT of the Temporal Bone: An Anatomical Study. Canadian Association of Radiologists Journal. 2024. doi:10.1177/08465371241234795

BibTeX
@article{Puel2024,
  author = {Puel, Ulysse and Eliezer, Michael and Boubaker, Fatma and Villani, Nicolas and Assabah, Bouchra and Hossu, Gabriela and Gondim Teixeira, Pedro Augusto and Blum, Alain and Parietti-Winkler, Cécile and Gillet, Romain},
  title = {Effect of Matrix Size and Acquisition Mode on Image Quality and Radiation Dose of Ultra-High-Resolution CT of the Temporal Bone: An Anatomical Study},
  journal = {Canadian Association of Radiologists Journal},
  year = {2024},
  doi = {10.1177/08465371241234795}
}
Kostenlos starten →