EUVIMEDEUVIMED entdecken
Crossref

Stiffness and energy storage characteristics of energy storage and return prosthetic feet

Nicholas D Womac, Richard R Neptune, Glenn K Klute

Prosthetics & Orthotics International · 2019-06 · 43 (3) · 266-275

DOI: 10.1177/0309364618823127 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Prosthetics & Orthotics International, 2019-06. Verfasst von Nicholas D Womac und 2 weiteren Autor:innen. Beteiligte Einrichtung: 1 The University of Texas at Austin, Austin, TX, USA. Hauptthemen laut MEDLINE: Artificial Limbs, Materials Testing, Mechanical Phenomena. Die Arbeit wurde bisher 30-mal zitiert (Crossref) und nennt 34 Literaturangaben. Gefördert von: RRD VA, U.S. Department of Veterans Affairs.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

BACKGROUND: Mechanical properties of prosthetic feet can significantly influence amputee gait, but how they vary with respect to limb loading and orientation is infrequently reported. OBJECTIVE: The objective of this study is to measure stiffness and energy storage characteristics of prosthetic feet across limb loading and a range of orientations experienced in typical gait. STUDY DESIGN: This study included mechanical testing. METHODS: Force-displacement data were collected at combinations of 15 sagittal and 5 coronal orientations and used to calculate stiffness and energy storage across prosthetic feet, stiffness categories, and heel wedge conditions. RESULTS: Stiffness and energy storage were highly non-linear in both the sagittal and coronal planes. Across all prosthetic feet, stiffness decreased with greater heel, forefoot, medial, and lateral orientations, while energy storage increased with forefoot, medial, and lateral loading orientations. Stiffness category was proportional to stiffness and inversely proportional to energy storage. Heel wedge effects were prosthetic foot dependent. CONCLUSION: Orientation, manufacturer, stiffness category, and heel wedge inclusion greatly influenced stiffness and energy storage characteristics. CLINICAL RELEVANCE: These results and an available graphical user interface tool may help improve clinical prescriptions by providing prosthetists with quantitative measures to compare prosthetic feet.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Artificial LimbsMaterials TestingMechanical PhenomenaFootGaitHumansProsthesis DesignRobotics

Stichwörter der Autor:innen

Prosthetic feetbiomechanicsenergy storageheel wedgestiffness

Autor:innen und Institutionen

  • 1 The University of Texas at Austin, Austin, TX, USA.
  • 2 Center for Limb Loss and MoBility, VA Puget Sound Health Care System, Seattle, WA, USA.
  • 3 University of Washington, Seattle, WA, USA.

Förderung

  • RRD VA
  • U.S. Department of Veterans Affairs

Zitieren

APA

Womac, N. D., Neptune, R. R., & Klute, G. K. (2019). Stiffness and energy storage characteristics of energy storage and return prosthetic feet. Prosthetics & Orthotics International, 43(3), 266-275. https://doi.org/10.1177/0309364618823127

Vancouver

Womac ND, Neptune RR, Klute GK. Stiffness and energy storage characteristics of energy storage and return prosthetic feet. Prosthetics & Orthotics International. 2019;43(3):266-275. doi:10.1177/0309364618823127

BibTeX
@article{Womac2019,
  author = {Womac, Nicholas D and Neptune, Richard R and Klute, Glenn K},
  title = {Stiffness and energy storage characteristics of energy storage and return prosthetic feet},
  journal = {Prosthetics & Orthotics International},
  year = {2019},
  volume = {43},
  number = {3},
  pages = {266--275},
  doi = {10.1177/0309364618823127}
}
Kostenlos starten →