EUVIMEDEUVIMED entdecken
Crossref

The use of dual and triple rule-out computerized tomography angiography by using diagnostic low-dose contrast material and radiation in acute chest pain

Ahmet Kerem Imrek iD, Mustafa Hızal, Yunus Yılmazsoy iD, Zeliha Coşgun iD

Acta Radiologica · 2025

DOI: 10.1177/02841851241298900 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Radiologica, 2025. Verfasst von Ahmet Kerem Imrek und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Bolu Abant Izzet Baysal University Faculty of Medicine Hospital, Bolu, Turkey. Hauptthemen laut MEDLINE: Contrast Media, Computed Tomography Angiography, Radiation Dosage, Chest Pain. Die Arbeit nennt 16 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Triple rule-out computed tomography angiography (CTA) provides imaging of the coronary arteries, pulmonary arteries, and thoracic aorta filled with contrast material (CM) to exclude or diagnose the pathologies of these three systems. Although dual rule-out adapted to exclude aortic and pulmonary pathologies. Iodinated CM may result in contrast-induced nephropathy, which lengthens hospital stay.

Purpose

To compare image quality of dual/triple rule-out CTA by reducing the radiation dose by using relatively high mAs with less contrast material and low kilovoltage without affecting the diagnostic value.

Methods

We acquired standard dual/triple rule-out CTA 120 kilovoltage peak (kVp) with 95 mL contrast material. The low-dose group acquired 80 Kvp with total 60 contrast material. There were 91 patients in the standard-dose group and 88 patients in the low-dose group.

Results

Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated separately. There was no significant difference in CNR values between the two groups in the aorta and pulmonary and coronary arteries; however, a significant difference was found in SNR values. In subjective image quality evaluation, no significant difference was found between the standard- and low-dose patients. The radiation dose was reduced by 63.80% and the contrast material by 31.5% in the low-dose group in comparison to the standard dose.

Conclusion

Our study showed that dual/triple rule-out CTA can be performed with low-dose radiation and low-volume contrast material. Low-dose CTA may be preferred in emergencies situations that patients with borderline renal function tests or the risk group.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Contrast MediaComputed Tomography AngiographyRadiation DosageChest PainHumansMaleFemaleMiddle AgedAgedSignal-To-Noise RatioAcute DiseaseAdultPulmonary ArteryRetrospective StudiesAged, 80 and overCoronary AngiographyAorta, Thoracic

Stichwörter der Autor:innen

Radiation dosecontrast materialdual/triple rule-out computed tomography angiographylow dose

Substanzen

Contrast Media

Autor:innen und Institutionen

  • Department of Radiology, Bolu Abant Izzet Baysal University Faculty of Medicine Hospital, Bolu, Turkey.

ORCID-Profile: Ahmet Kerem Imrek, Yunus Yılmazsoy, Zeliha Coşgun

Zitieren

APA

Imrek, A. K., Hızal, M., Yılmazsoy, Y., & Coşgun, Z. (2025). The use of dual and triple rule-out computerized tomography angiography by using diagnostic low-dose contrast material and radiation in acute chest pain. Acta Radiologica. https://doi.org/10.1177/02841851241298900

Vancouver

Imrek AK, Hızal M, Yılmazsoy Y, Coşgun Z. The use of dual and triple rule-out computerized tomography angiography by using diagnostic low-dose contrast material and radiation in acute chest pain. Acta Radiologica. 2025. doi:10.1177/02841851241298900

BibTeX
@article{Imrek2025,
  author = {Imrek, Ahmet Kerem and Hızal, Mustafa and Yılmazsoy, Yunus and Coşgun, Zeliha},
  title = {The use of dual and triple rule-out computerized tomography angiography by using diagnostic low-dose contrast material and radiation in acute chest pain},
  journal = {Acta Radiologica},
  year = {2025},
  doi = {10.1177/02841851241298900}
}
Kostenlos starten →