EUVIMEDEUVIMED entdecken
Crossref

Can smartphone cameras help with diagnostic adequacy in renal biopsy?

Mehmet Karagulle iD, Sıbel Hamarat Gulcicek, Emin Taha Keskin

Acta Radiologica · 2025

DOI: 10.1177/02841851241295393 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Acta Radiologica, 2025. Verfasst von Mehmet Karagulle und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Health Sciences, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey. Hauptthemen laut MEDLINE: Smartphone, Image-Guided Biopsy, Ultrasonography, Interventional, Kidney Diseases. Die Arbeit nennt 15 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

In this prospective study, we evaluated whether a sufficient number of glomeruli were achieved using the 8× magnification of smartphone cameras.

Purpose

To increase the percutaneous ultrasound-guided renal biopsy (PURB) diagnostic value with a method that has not been tried before and reduce the need for repetition of the procedure. Material and Methods A total of 39 adult patients who underwent PURB were included in our study. After the PURB was applied to the patients, the biopsy specimen was placed on the previously prepared sterile gauze. At this stage, 8× magnification photos were taken of the biopsy samples using the smartphone camera. The glomeruli in the photograph were counted and recorded and compared with the number of glomeruli seen at the end of the histopathological examination.

Results

The mean number of glomeruli in the evaluated samples was counted as 6 ± 2.2 (range = 1–10) in the 8× magnification photograph. The mean number of glomeruli detected in the histopathological examination of these samples was 11 ± 5.7 (range = 2–30). A pathological glomeruli count of 10 was associated with more than five brown spots in the 8× magnification photograph (area under the curve = 0.977, P=0.0001).

Conclusion

To obtain more than 10 glomeruli in a PURB specimen, five or more brownish-red dots should be counted on the 8x magnification photograph. Using smartphones as an alternative tool for evaluating renal biopsy tissue adequacy can be practical and advantageous in terms of time and labor.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SmartphoneImage-Guided BiopsyUltrasonography, InterventionalKidney DiseasesKidneyKidney GlomerulusHumansFemaleMaleMiddle AgedProspective StudiesAdultAged

Stichwörter der Autor:innen

Biopsyglomeruluskidneysmartphone camera

Autor:innen und Institutionen

  • Department of Radiology, University of Health Sciences, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey.
  • Department of Nephrology, Istanbul Education and Research Hospital, Istanbul, Turkey.
  • Department of Urology, University of Health Sciences, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey.

ORCID-Profile: Mehmet Karagulle

Zitieren

APA

Karagulle, M., Gulcicek, S. H., & Keskin, E. T. (2025). Can smartphone cameras help with diagnostic adequacy in renal biopsy?. Acta Radiologica. https://doi.org/10.1177/02841851241295393

Vancouver

Karagulle M, Gulcicek SH, Keskin ET. Can smartphone cameras help with diagnostic adequacy in renal biopsy?. Acta Radiologica. 2025. doi:10.1177/02841851241295393

BibTeX
@article{Karagulle2025,
  author = {Karagulle, Mehmet and Gulcicek, Sıbel Hamarat and Keskin, Emin Taha},
  title = {Can smartphone cameras help with diagnostic adequacy in renal biopsy?},
  journal = {Acta Radiologica},
  year = {2025},
  doi = {10.1177/02841851241295393}
}
Kostenlos starten →