EUVIMEDEUVIMED entdecken
VergleichsstudieBeobachtungsstudie

Comparison of Cytological Adequacy between 23- and 25-Gauge in Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules: A Single-Center Prospective Study

Francisca Marques Puga, Inês Poças Ferreira, José Ricardo Brandão, Liliana Fonseca, André Couto de Carvalho, Cláudia Freitas

Acta Cytologica · 2024

DOI: 10.1159/000538290 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Acta Cytologica, 2024. Verfasst von Francisca Marques Puga und 5 weiteren Autor:innen. Beteiligte Einrichtung: Serviço de Endocrinologia, Diabetes e Metabolismo, Centro Hospitalar Universitário de Santo António, Porto, Portugal. Hauptthemen laut MEDLINE: Thyroid Nodule. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 29 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Approximately 15% of fine-needle aspiration (FNA) of thyroid nodules are considered nondiagnostic. Several factors are potentially involved, including clinical and nodule features but also the gauge (G) of the needle used. However, few studies have compared the cytological adequacy obtained with different gauge needles and the data are controversial. We aimed to evaluate cytological adequacy results using 23- or 25-G needles.

Methods

This study is an observational and prospective study of thyroid nodules submitted to ultrasound-guided FNA. The procedure was performed randomly using 23- or 25-G needles. The samples were reported by different cytopathologists who were blinded to the information of the gauge of the needle used. Statistical analysis was performed to compare cytological adequacy of FNA between the two groups.

Results

A total of 177 thyroid nodules were included – 98 (55.4%) using 23-G and 79 (44.6%) using 25-G needles. The 23-G group presented a higher rate of cytological adequacy (69.4% [68/98] vs. 46.8% [37/79], p = 0.002). No differences were found between the two groups regarding patient or nodule characteristics. On logistic regression, 23-G needles correlated with better cytological adequacy (unadjusted OR 2.57 [95% CI: 1.39–4.77]), even after adjusting for nodule dimension, location, and type of cytology (slides +/− additional liquid-based cytology) (adjusted OR 2.44 [95% CI: 1.23–4.84]).

Conclusion

The gauge of the needle used was found to be an independent predictor of cytological adequacy, with 23-G needles providing more adequate samples. Further investigation is needed to confirm our results in order to stablish the optimal diagnosis technique.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Thyroid NoduleHumansProspective StudiesFemaleMaleMiddle AgedAdultBiopsy, Fine-NeedleAgedNeedlesUltrasonography, InterventionalReproducibility of ResultsPredictive Value of TestsEquipment DesignImage-Guided BiopsyThyroid Gland

Stichwörter der Autor:innen

Cytological adequacyGaugeNeedleNondiagnostic resultsThyroid noduleUltrasound-guided fine-needle aspiration

Autor:innen und Institutionen

  • Serviço de Endocrinologia, Diabetes e Metabolismo, Centro Hospitalar Universitário de Santo António, Porto, Portugal.
  • Serviço de Anatomia Patológica, Centro Hospitalar Universitário de Santo António, Porto, Portugal.

Zitieren

APA

Puga, F. M., Ferreira, I. P., Brandão, J. R., Fonseca, L., Couto de Carvalho, A., & Freitas, C. (2024). Comparison of Cytological Adequacy between 23- and 25-Gauge in Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules: A Single-Center Prospective Study. Acta Cytologica. https://doi.org/10.1159/000538290

Vancouver

Puga FM, Ferreira IP, Brandão JR, Fonseca L, Couto de Carvalho A, Freitas C. Comparison of Cytological Adequacy between 23- and 25-Gauge in Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules: A Single-Center Prospective Study. Acta Cytologica. 2024. doi:10.1159/000538290

BibTeX
@article{Puga2024,
  author = {Puga, Francisca Marques and Ferreira, Inês Poças and Brandão, José Ricardo and Fonseca, Liliana and Couto de Carvalho, André and Freitas, Cláudia},
  title = {Comparison of Cytological Adequacy between 23- and 25-Gauge in Ultrasound-Guided Fine-Needle Aspiration of Thyroid Nodules: A Single-Center Prospective Study},
  journal = {Acta Cytologica},
  year = {2024},
  doi = {10.1159/000538290}
}
Kostenlos starten →