EUVIMEDEUVIMED entdecken
Metaanalyse

The diagnostic value of CT-guided percutaneous puncture biopsy of pulmonary ground-glass nodules: a meta-analysis

Binchen Wang, Feiyang Zhong, Wenting An, Meiyan Liao iD

Acta Radiologica · 2023-04 · 64 (4) · 1431-1438

DOI: 10.1177/02841851221137693 ↗

Kurz gefasst

Metaanalyse in der Zeitschrift Acta Radiologica, online erschienen am 15.11.2022. Verfasst von Binchen Wang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, 89674Zhongnan Hospital of Wuhan University, Wuhan, PR China. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Multiple Pulmonary Nodules. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 23 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

More and more pulmonary ground-glass nodules (GGNs) are screened with the extensive usage of low-dose computed tomography (CT). The need of CT-guided percutaneous puncture biopsy of GGN remains controversial.

Purpose

To explore the diagnostic accuracy of CT-guided percutaneous puncture biopsy of GGNs. Material and Methods We searched PubMed, EMBASE, the Cochrane Library, and CNKI. Included studies reported the puncture biopsy results of pulmonary GGNs, including the number of true positive (TP), false positive (FP), true negative (TN), and false negative (FN) cases. After evaluating the studies, statistical analysis, and quality assessment, the pooled diagnostic sensitivity (SEN), specificity (SPE), and diagnostic odds ratio (DOR) were calculated. The summary receiver operating characteristic (SROC) curve was constructed and the area under the curve (AUC) was calculated. Subgroup analysis was performed according to whether spiral CT or fluoroscopy-guided CT was used in the study.

Results

This meta-analysis included 14 studies with a total of 759 patients (702 samples). The pooled SEN, SPE, and DOR of CT-guided puncture biopsy of pulmonary GGNs were 0.91 (95% confidence interval [CI] = 0.89–0.94), 0.99 (95% CI = 0.95–1.00), and 138.72 (95% CI = 57.98–331.89), respectively. The AUC was 0.97.

Conclusion

Our results indicated that CT-guided puncture biopsy of GGNs has high SEN, SPE, and DOR, which proved that CT-guided puncture biopsy was a good way to determine the pathological nature of GGN.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedMultiple Pulmonary NodulesHumansTomography, Spiral ComputedSensitivity and SpecificityBiopsy, Needle

Stichwörter der Autor:innen

Ground-glass nodulesbiopsycomputed tomographymeta-analysispuncture

Autor:innen und Institutionen

  • Department of Radiology, 89674Zhongnan Hospital of Wuhan University, Wuhan, PR China.

ORCID-Profile: Meiyan Liao

Zitieren

APA

Wang, B., Zhong, F., An, W., & Liao, M. (2023). The diagnostic value of CT-guided percutaneous puncture biopsy of pulmonary ground-glass nodules: a meta-analysis. Acta Radiologica, 64(4), 1431-1438. https://doi.org/10.1177/02841851221137693

Vancouver

Wang B, Zhong F, An W, Liao M. The diagnostic value of CT-guided percutaneous puncture biopsy of pulmonary ground-glass nodules: a meta-analysis. Acta Radiologica. 2023;64(4):1431-1438. doi:10.1177/02841851221137693

BibTeX
@article{Wang2023,
  author = {Wang, Binchen and Zhong, Feiyang and An, Wenting and Liao, Meiyan},
  title = {The diagnostic value of CT-guided percutaneous puncture biopsy of pulmonary ground-glass nodules: a meta-analysis},
  journal = {Acta Radiologica},
  year = {2023},
  volume = {64},
  number = {4},
  pages = {1431--1438},
  doi = {10.1177/02841851221137693}
}
Kostenlos starten →