EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitSystematische ÜbersichtMetaanalyse

Impact of dynamic pump speed adjustment versus constant speed in left ventricle assist device patients on exercise performance: A systematic review and meta-analysis

Sarah Quick Lourenço de Lima iD, Vitória Freitas Silva, Matheus de Medeiros Fernandes, Rafaela Pereira Silva, João Filipe Cavalcante Uchoa Furtado, Lívia Liberata Barbosa Bandeira, Juliana Giorgi, Rodolfo Alves Lopes

Perfusion · 18.11.2026

DOI: 10.1177/02676591261508706 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Perfusion, online erschienen am 18.11.2026. Verfasst von Sarah Quick Lourenço de Lima und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Medicine, Federal University of Juiz de Fora, Juiz de Fora, Minas Gerais, Brazil. Die Arbeit nennt 24 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Adjusting pump speed in patients with left ventricular assist devices (LVADs) during exercise may improve hemodynamics and enhance functional capacity in advanced heart failure, but its clinical benefit over fixed-speed operation remains uncertain. We evaluated whether dynamic, exercise-driven LVAD speed modulation improves physical performance compared to fixed-speed settings. Methods and results PubMed, Embase, and the Cochrane Library were systematically searched for studies comparing dynamic adjustment versus fixed pump speed control during exercise in patients with LVADs. Continuous outcomes were analyzed using mean differences (MD), and binary outcomes using risk ratios (RR), with 95% confidence intervals (CIs). Statistical analysis was performed using R (version 4.3.1). Eight studies were included, with study sample sizes totaling 124 participants; seven used crossover designs and one used a non-randomized repeated-measures design. Potential overlap between two reports from Jung et al. precluded interpretation of this total as the number of unique participants. Dynamic pump-speed modulation was associated with higher peak oxygen uptake (VO 2 ) (MD 1.07 mL/kg/min; 95% CI 0.73 to 1.41; p < 0.001; I 2 = 42%) and LVAD pump flow at peak/end of exercise (MD 1.24 L/min; 95% CI 0.68 to 1.79; p < 0.001; I 2 = 89%). No differences were observed in peak cardiac output (MD 0.12 L/min; 95% CI −0.74 to 0.98; p = 0.786; I 2 = 67%) or ventilatory efficiency, assessed by the VE/VCO 2 slope (MD −1.58; 95% CI −3.25 to 0.09; p = 0.063; I 2 = 76%).

Conclusion

Dynamic LVAD speed adjustment may improve exercise capacity, as suggested by higher peak VO 2 , although peak cardiac output and ventilatory efficiency showed no clear improvement. Given the small studies, heterogeneous protocols and possible participant overlap, it remains uncertain whether this apparent benefit is sustained or clinically meaningful to patients.

Schlagwörter

Stichwörter der Autor:innen

LVADadvanced heart failureexerciseheart failureleft ventricular assist devicephysical activity

Autor:innen und Institutionen

  • Department of Medicine, Federal University of Juiz de Fora, Juiz de Fora, Minas Gerais, Brazil.
  • Department of Cardiology, Heart Institute (Incor), University of São Paulo Medical School, São Paulo, São Paulo, Brazil.
  • Department of Medicine, State University of Rio Grande do Norte, Mossoró, Rio Grande do Norte, Brazil.
  • Department of Medicine, Federal University of Maranhão, São Luís, Maranhão, Brazil.
  • Department of Medicine, University of Fortaleza, Fortaleza, Ceará, Brazil.
  • Department of Medicine, Norwich Medical School, University of East Anglia, Norwich, UK.

ORCID-Profile: Sarah Quick Lourenço de Lima

Zitieren

APA

Quick Lourenço de Lima, S., Freitas Silva, V., de Medeiros Fernandes, M., Pereira Silva, R., Filipe Cavalcante Uchoa Furtado, J., Liberata Barbosa Bandeira, L., Giorgi, J., & Alves Lopes, R. (2026). Impact of dynamic pump speed adjustment versus constant speed in left ventricle assist device patients on exercise performance: A systematic review and meta-analysis. Perfusion. https://doi.org/10.1177/02676591261508706

Vancouver

Quick Lourenço de Lima S, Freitas Silva V, de Medeiros Fernandes M, Pereira Silva R, Filipe Cavalcante Uchoa Furtado J, Liberata Barbosa Bandeira L, et al. Impact of dynamic pump speed adjustment versus constant speed in left ventricle assist device patients on exercise performance: A systematic review and meta-analysis. Perfusion. 2026. doi:10.1177/02676591261508706

BibTeX
@article{QuickLourenodeLima2026,
  author = {Quick Lourenço de Lima, Sarah and Freitas Silva, Vitória and de Medeiros Fernandes, Matheus and Pereira Silva, Rafaela and Filipe Cavalcante Uchoa Furtado, João and Liberata Barbosa Bandeira, Lívia and Giorgi, Juliana and Alves Lopes, Rodolfo},
  title = {Impact of dynamic pump speed adjustment versus constant speed in left ventricle assist device patients on exercise performance: A systematic review and meta-analysis},
  journal = {Perfusion},
  year = {2026},
  doi = {10.1177/02676591261508706}
}
Kostenlos starten →