Outcomes of concomitant aortic valve procedures and left ventricular assist device implantation: A systematic review and meta‐analysis
Artificial Organs · 2023-03 · 47 (3) · 470-480
DOI: 10.1111/aor.14482 ↗Kurz gefasst
Metaanalyse in der Zeitschrift Artificial Organs, online erschienen am 20.12.2022. Verfasst von Kinza Iqbal und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Internal Medicine, Dow Medical College, Dow University of Health Sciences, Karachi, Pakistan. Hauptthemen laut MEDLINE: Heart Failure, Heart-Assist Devices, Thoracic Surgical Procedures. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
Left ventricular assist device (LVAD) implantation is frequently employed in patients with end‐stage heart failure. The outcomes of addressing the repair of all substantial aortic valvular disease at the time of LVAD implantation remain unclear. We sought to assess the clinical outcomes in patients undergoing LVAD implantation concomitant with aortic valve procedures (AVPs) compared with isolated LVAD implantation.
Methods
A literature search was performed using PubMed, Embase, and Cochrane library from inception till June 2022. Primary outcomes included short‐term mortality and long‐term survival. Random effects models were used to compute mean differences and odds ratios with 95% confidence intervals (CIs).
Results
A total of 14 observational studies ( N = 52 693) met our inclusion criteria. Concomitant LVAD implantation and AVPs were associated with higher short‐term mortality (OR = 1.61 [95% CI, 1.06–2.42]; p = 0.02) and mean CPBt (MD = 43.25 [95% CI, 22.95–63.56]; p < 0.0001), and reduced long‐term survival (OR = 0.70 [95% CI, 0.55–0.88]; p = 0.003) compared with isolated LVAD implantation. No difference in the odds of cerebrovascular accident (OR = 1.05 [95% CI, 0.79–1.39]; p = 0.74) and mean length of hospital stay (MD = 2.89 [95% CI, −4.04 to 9.82]; p = 0.41) was observed between the two groups. On adjusted analysis, short‐term mortality was significantly higher in the LVAD group with concurrent AVPs when compared with the isolated LVAD group (aHR = 1.50 [95% CI, 1.20–1.87]; p = 0.0004).
Conclusions
Concurrent AVPs were associated with higher short‐term mortality and reduced long‐term survival in patients undergoing LVAD implantation compared with isolated LVAD implantation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Internal Medicine, Dow Medical College, Dow University of Health Sciences, Karachi, Pakistan.
- Department of Internal Medicine, Dr. Sampurnanand Medical College, Jodhpur, India.
- Department of Internal Medicine, Ziauddin Medical University, Karachi, Pakistan.
- Department of Surgery, Mayo Clinic, Rochester, New York, USA.
- Department of Internal Medicine, Cleveland Clinic Akron General, Akron, Ohio, USA.
- Section of Cardiovascular Research, Heart, Vascular and Thoracic Department, Cleveland Clinic Akron General, Akron, Ohio, USA.
ORCID-Profile: Kinza Iqbal
Zitieren
APA
Iqbal, K., Arif, T. B., Rathore, S. S., Ahmed, J., Kumar, P., Shahid, I., Iqbal, A., Shariff, M., & Kumar, A. (2023). Outcomes of concomitant aortic valve procedures and left ventricular assist device implantation: A systematic review and meta‐analysis. Artificial Organs, 47(3), 470-480. https://doi.org/10.1111/aor.14482
Vancouver
Iqbal K, Arif TB, Rathore SS, Ahmed J, Kumar P, Shahid I, et al. Outcomes of concomitant aortic valve procedures and left ventricular assist device implantation: A systematic review and meta‐analysis. Artificial Organs. 2023;47(3):470-480. doi:10.1111/aor.14482
BibTeX
@article{Iqbal2023,
author = {Iqbal, Kinza and Arif, Taha Bin and Rathore, Sawai Singh and Ahmed, Jawad and Kumar, Pankaj and Shahid, Izza and Iqbal, Ayman and Shariff, Mariam and Kumar, Ashish},
title = {Outcomes of concomitant aortic valve procedures and left ventricular assist device implantation: A systematic review and meta‐analysis},
journal = {Artificial Organs},
year = {2023},
volume = {47},
number = {3},
pages = {470--480},
doi = {10.1111/aor.14482}
}