EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparative analysis of oxygenator dysfunction in polymethylpentene oxygenators: A pilot study

Shan P Modi iD, Brandon D'Aloiso, Amber Palmer, Stephanie Smith, Peter Arlia, Michael Anselmi, Pablo Sanchez, Raj Ramanan

Perfusion · 2025

DOI: 10.1177/02676591241268402 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Perfusion, 2025. Verfasst von Shan P Modi und 7 weiteren Autor:innen. Beteiligte Einrichtung: Cardiovascular Institute, Allegheny Health Network, Pittsburgh, PA, USA. Hauptthemen laut MEDLINE: Extracorporeal Membrane Oxygenation, Oxygenators, Membrane. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 19 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Polymethylpentene (PMP) oxygenators serve as the primary oxygenator type utilized for ECMO. With the number of PMP oxygenators available, it has become increasingly important to determine differences among each oxygenator type that can lead to varying metrics of oxygenator dysfunction.

Methods

This study was a retrospective, single-center analysis of adult patients supported on ECMO between December 2020 to December 2021 with varying PMP oxygenators including the Medtronic Nautilus Smart (Minneapolis, MA), the Eurosets AMG PMP (Medolla, Italy) and Getinge Quadrox-iD and the Getinge Cardiohelp HLS Module Advanced System (Gothenberg, Sweden).

Results

A total of 19 patients were included in our study. 10 patients (52.6%) were supported with a Medtronic Nautilus Smart oxygenator, 5 patients (26.3%) were supported with an Eurosets AMG PMP Oxygenator, and 4 patients (21.1%) were supported with either a Getinge Quadrox-iD oxygenator or Getinge Cardiohelp HLS system. Patients supported with Eurosets AMG PMP oxygenators experienced higher resistance and lower post-oxygenator PaO 2 in comparison to other cohorts ( p < .02 and < .002 respectively). There was no difference in measured oxygen transfer between cohorts ( p = .667). Two patients, both supported by Eurosets AMG PMP, experienced oxygenator failure ( p = . 094).

Conclusion

Radial flow oxygenators are prone to higher resistance and lower post-oxygenator PaO 2 when compared to transverse flow oxygenators. Future larger multicenter studies are required to fully discern the differences between flow-varying polymethylpentene oxygenators and their appropriate cutoffs for oxygenator dysfunction.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Extracorporeal Membrane OxygenationOxygenators, MembraneHumansMaleRetrospective StudiesFemalePilot ProjectsMiddle AgedAdultAged

Stichwörter der Autor:innen

extracorporeal membrane oxygenationoxygen transferoxygenatorpolymethylpentene

Autor:innen und Institutionen

  • Cardiovascular Institute, Allegheny Health Network, Pittsburgh, PA, USA.
  • Perfusion Services, Procirca, University of Pittsburgh Medical Center, Pittsburgh, PA, USA.
  • Heart and Vascular Institute, West Virginia University, Morgantown, WV, USA.
  • Department of Cardiothoracic Surgery, University of Pittsburgh, Pittsburgh, PA, USA.
  • Department of Critical Care Medicine, University of Pittsburgh, Pittsburgh, PA, USA.

ORCID-Profile: Shan P Modi

Zitieren

APA

Modi, S. P., D'Aloiso, B., Palmer, A., Smith, S., Arlia, P., Anselmi, M., Sanchez, P., & Ramanan, R. (2025). Comparative analysis of oxygenator dysfunction in polymethylpentene oxygenators: A pilot study. Perfusion. https://doi.org/10.1177/02676591241268402

Vancouver

Modi SP, D'Aloiso B, Palmer A, Smith S, Arlia P, Anselmi M, et al. Comparative analysis of oxygenator dysfunction in polymethylpentene oxygenators: A pilot study. Perfusion. 2025. doi:10.1177/02676591241268402

BibTeX
@article{Modi2025,
  author = {Modi, Shan P and D'Aloiso, Brandon and Palmer, Amber and Smith, Stephanie and Arlia, Peter and Anselmi, Michael and Sanchez, Pablo and Ramanan, Raj},
  title = {Comparative analysis of oxygenator dysfunction in polymethylpentene oxygenators: A pilot study},
  journal = {Perfusion},
  year = {2025},
  doi = {10.1177/02676591241268402}
}
Kostenlos starten →