Computational fluid dynamics analysis of endoluminal aortic perfusion
Perfusion · 2023-09 · 38 (6) · 1222-1229
DOI: 10.1177/02676591221099809 ↗Kurz gefasst
Fachartikel in der Zeitschrift Perfusion, online erschienen am 12.05.2022. Verfasst von Daniel Malinowski und 9 weiteren Autor:innen. Beteiligte Einrichtung: Institute for Bioengineering, Biomaterials Laboratory, University of Applied Sciences Aachen, Aachen, Germany. Hauptthemen laut MEDLINE: Hydrodynamics, Aorta. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Introduction
In peripheral percutaneous (VA) extracorporeal membrane oxygenation (ECMO) procedures the femoral arteries perfusion route has inherent disadvantages regarding poor upper body perfusion due to watershed. With the advent of new long flexible cannulas an advancement of the tip up to the ascending aorta has become feasible. To investigate the impact of such long endoluminal cannulas on upper body perfusion, a Computational Fluid Dynamics (CFD) study was performed considering different support levels and three cannula positions.
Methods
An idealized literature-based- and a real patient proximal aortic geometry including an endoluminal cannula were constructed. The blood flow was considered continuous. Oxygen saturation was set to 80% for the blood coming from the heart and to 100% for the blood leaving the cannula. 50% and 90% venoarterial support levels from the total blood flow rate of 6 l/min were investigated for three different positions of the cannula in the aortic arch.
Results
For both geometries, the placement of the cannula in the ascending aorta led to a superior oxygenation of all aortic blood vessels except for the left coronary artery. Cannula placements at the aortic arch and descending aorta could support supra-aortic arteries, but not the coronary arteries. All positions were able to support all branches with saturated blood at 90% flow volume.
Conclusions
In accordance with clinical observations CFD analysis reveals, that retrograde advancement of a long endoluminal cannula can considerably improve the oxygenation of the upper body and lead to oxygen saturation distributions similar to those of a central cannulation.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Institute for Bioengineering, Biomaterials Laboratory, University of Applied Sciences Aachen, Aachen, Germany.
- Fluid Mechanics, Energy and Environment Dpt., EDF R&D, Chatou, France.
- Department of Cardiology, Angiology, and Intensive Care, University Hospital Medical Faculty, RWTH Aachen University, Aachen, Germany.
- Division of Thoracic Surgery and Thoracic Organ Support, University Hospital Medical Faculty, RWTH Aachen University, Aachen, Germany.
ORCID-Profile: Daniel Malinowski, Jan Spillner, Mehdi Behbahani, Flutura Hima
Zitieren
APA
Malinowski, D., Fournier, Y., Horbach, A., Frick, M., Magliani, M., Kalverkamp, S., Hildinger, M., Spillner, J., Behbahani, M., & Hima, F. (2023). Computational fluid dynamics analysis of endoluminal aortic perfusion. Perfusion, 38(6), 1222-1229. https://doi.org/10.1177/02676591221099809
Vancouver
Malinowski D, Fournier Y, Horbach A, Frick M, Magliani M, Kalverkamp S, et al. Computational fluid dynamics analysis of endoluminal aortic perfusion. Perfusion. 2023;38(6):1222-1229. doi:10.1177/02676591221099809
BibTeX
@article{Malinowski2023,
author = {Malinowski, Daniel and Fournier, Yvan and Horbach, Andreas and Frick, Michael and Magliani, Mirko and Kalverkamp, Sebastian and Hildinger, Martin and Spillner, Jan and Behbahani, Mehdi and Hima, Flutura},
title = {Computational fluid dynamics analysis of endoluminal aortic perfusion},
journal = {Perfusion},
year = {2023},
volume = {38},
number = {6},
pages = {1222--1229},
doi = {10.1177/02676591221099809}
}
EUVIMED