Reverse cannulation method as a strategy for aortic aneurysm surgery: A computational fluid dynamics study on minimizing neurological risks
The Journal of Thoracic and Cardiovascular Surgery · 2025
DOI: 10.1016/j.jtcvs.2024.07.047 ↗Kurz gefasst
Fachartikel in der Zeitschrift The Journal of Thoracic and Cardiovascular Surgery, 2025. Verfasst von Yuki Imamura und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Thoracic and Cardiovascular Surgery, Hirosaki University School of Medicine, Hirosaki, Japan. Hauptthemen laut MEDLINE: Models, Cardiovascular, Aorta, Thoracic, Aortic Aneurysm, Thoracic, Blood Vessel Prosthesis Implantation. Die Arbeit nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
OBJECTIVES: To evaluate the blood flow velocity and wall shear stress in total arch replacement with a "shaggy" aorta, using computational fluid dynamics, and determine the optimal cannulation method. METHODS: A patient-specific aortic arch aneurysm model was constructed by using computed tomography scans. Three cannulas were assessed, as follows: dispersive with a steep angle, dispersive with a gentle angle, and the endo-hole type. The cannula tips were oriented toward the aortic arch (standard direction) and aortic root (reversed direction), with an ideal angle (base orientation: 0°), tip orientations rotated 20° clockwise and counterclockwise from the base orientation. The variables of interest included the blood flow velocity, streamlines, wall shear stress, and flow distribution. RESULTS: The standard direction resulted in variable accelerated flow and wall shear stress locations based on cannula tip orientation, leading to unstable cerebral branch flow. Minor deviation in the cannula tip angle and cannula type led to significant alterations in flow distribution. Conversely, in the reverse direction for all cannulas, no accelerated blood flow was observed in the proximal aortic arch or cerebral vessel ostia even with angular adjustments, helping maintain a stable cerebral branch flow. Minimal variation in blood flow distribution was observed across all cannula types and angles. CONCLUSIONS: Our simulations indicate that, irrespective of the cannula type or orientation, directing the cannula tip toward the aortic root (reversed direction) prevents accelerated blood flow in critical areas, suggesting its potential as an optimal approach for aortic arch surgery in "shaggy" aorta cases.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Thoracic and Cardiovascular Surgery, Hirosaki University School of Medicine, Hirosaki, Japan.
- Division of Simcenter Support, Department of CCM, Siemens K.K., Tokyo, Japan.
- Department of Thoracic and Cardiovascular Surgery, Hirosaki University School of Medicine, Hirosaki, Japan. Electronic address: kowatari@hirosaki-u.ac.jp.
Zitieren
APA
Imamura, Y., Takayama, Y., Kowatari, R., & Minakawa, M. (2025). Reverse cannulation method as a strategy for aortic aneurysm surgery: A computational fluid dynamics study on minimizing neurological risks. The Journal of Thoracic and Cardiovascular Surgery. https://doi.org/10.1016/j.jtcvs.2024.07.047
Vancouver
Imamura Y, Takayama Y, Kowatari R, Minakawa M. Reverse cannulation method as a strategy for aortic aneurysm surgery: A computational fluid dynamics study on minimizing neurological risks. The Journal of Thoracic and Cardiovascular Surgery. 2025. doi:10.1016/j.jtcvs.2024.07.047
BibTeX
@article{Imamura2025,
author = {Imamura, Yuki and Takayama, Yoshishige and Kowatari, Ryosuke and Minakawa, Masahito},
title = {Reverse cannulation method as a strategy for aortic aneurysm surgery: A computational fluid dynamics study on minimizing neurological risks},
journal = {The Journal of Thoracic and Cardiovascular Surgery},
year = {2025},
doi = {10.1016/j.jtcvs.2024.07.047}
}
EUVIMED