Early and midterm outcomes of Frozenix Partial-ET versus conventional Frozenix in total arch replacement for acute type A aortic dissection
Asian Cardiovascular and Thoracic Annals · 2026-06 · 34 (5) · 445-451
DOI: 10.1177/02184923261440414 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Asian Cardiovascular and Thoracic Annals, online erschienen am 15.04.2026. Verfasst von Ryumon Matsumoto und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiovascular Surgery, Tsuchiura Kyodo General Hospital, Tsuchiura, Japan. Hauptthemen laut MEDLINE: Dissection, Ascending Aorta, Blood Vessel Prosthesis Implantation, Blood Vessel Prosthesis, Aortic Aneurysm, Thoracic. Die Arbeit nennt 17 Literaturangaben.
Abstract (Originalsprache)
Background
In this study, we sought to evaluate the early outcomes and aortic remodeling effects of the Frozenix Partial-ET in total arch replacement for acute type A aortic dissection, and its potential to reduce distal stent graft-induced new entry (dSINE).
Methods
We retrospectively analyzed 47 patients who underwent total arch replacement with a frozen elephant trunk (FET) between January 2017 and December 2024, among whom, 34 received the conventional Frozenix (Full-FET group), and 13 received the Frozenix Partial-ET (Partial-ET group). Clinical outcomes, CT-based morphological parameters, and aortic remodeling were compared.
Results
There were no significant differences between the two groups regarding mortality or major complications. Patients in the Partial-ET group had greater distal stent angulation (34.5 ± 8.9° vs. 24.5 ± 13.7°), and no dSINE was observed during a mean follow-up period of 6.4 months. Aortic remodeling outcomes were comparable between the two groups, while the Partial-ET group demonstrated shorter lower body ischemia time and more proximal distal stent deployment.
Conclusions
Application of Frozenix Partial-ET resulted in outcomes comparable to those obtained using the conventional device, without an increase in mortality or major complications. Despite a greater distal angulation, no early dSINE was observed during the study period. This device may represent a feasible option in selected cases of acute type A dissection, although further long-term data are needed to clarify its efficacy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Cardiovascular Surgery, Tsuchiura Kyodo General Hospital, Tsuchiura, Japan.
- Department of Cardiovascular Surgery, Tokyo Medical University Hospital, Tokyo, Japan.
- Department of Cardiovascular Surgery, Medical Research Institute Kitano Hospital, Osaka, Japan.
ORCID-Profile: Ryumon Matsumoto, Ryoji Kinoshita
Zitieren
APA
Matsumoto, R., Kinoshita, R., Watanabe, T., Shimahara, Y., & Ogino, H. (2026). Early and midterm outcomes of Frozenix Partial-ET versus conventional Frozenix in total arch replacement for acute type A aortic dissection. Asian Cardiovascular and Thoracic Annals, 34(5), 445-451. https://doi.org/10.1177/02184923261440414
Vancouver
Matsumoto R, Kinoshita R, Watanabe T, Shimahara Y, Ogino H. Early and midterm outcomes of Frozenix Partial-ET versus conventional Frozenix in total arch replacement for acute type A aortic dissection. Asian Cardiovascular and Thoracic Annals. 2026;34(5):445-451. doi:10.1177/02184923261440414
BibTeX
@article{Matsumoto2026,
author = {Matsumoto, Ryumon and Kinoshita, Ryoji and Watanabe, Taiju and Shimahara, Yusuke and Ogino, Hitoshi},
title = {Early and midterm outcomes of Frozenix Partial-ET versus conventional Frozenix in total arch replacement for acute type A aortic dissection},
journal = {Asian Cardiovascular and Thoracic Annals},
year = {2026},
volume = {34},
number = {5},
pages = {445--451},
doi = {10.1177/02184923261440414}
}
EUVIMED