Thoracic Endovascular Repair for Retrograde Type A Aortic Dissection: True Lumen Device Sizing
Annals of Vascular Surgery · 2026
DOI: 10.1016/j.avsg.2026.06.016 ↗Kurz gefasst
Fachartikel in der Zeitschrift Annals of Vascular Surgery, 2026. Verfasst von Ryo Onishi und 11 weiteren Autor:innen. Beteiligte Einrichtung: Division of Thoracic and Cardiovascular Surgery, Niigata University Graduate School of Medical and Dental Sciences, Niigata City, Niigata, Japan. Hauptthemen laut MEDLINE: Endovascular Aneurysm Repair, Blood Vessel Prosthesis, Stents, Dissection, Ascending Aorta. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 18 Literaturangaben.
Abstract (Originalsprache)
BACKGROUND: Optimal device sizing for retrograde type A aortic dissection during thoracic endovascular aortic repair (TEVAR) remains challenging because the true lumen at the proximal landing zone is frequently compressed and elliptical. This study evaluated the clinical outcomes and investigated how true lumen morphology influences device selection. METHODS: Between October 2012 and December 2022, 34 retrograde type A aortic dissection patients underwent TEVAR. Patients with major cardiac or neurological complications were excluded. We retrospectively analyzed the clinical and anatomical outcomes, focusing on postoperative remodeling. Preoperative computed tomography evaluated the relationship between the proximal landing true lumen morphology and device sizing. RESULTS: The mean patient age was 62.7 ± 10.9 years. Emergency TEVAR was performed in 21 patients (61.8%) on the day of onset. Perioperative complications included one spinal cord infarction and no cerebral infarctions. Five patients required additional procedures for a residual entry flow. During the follow-up, the ascending aortic false lumen disappeared in 30 patients (88%). One in-hospital death occurred due to retrograde type A dissection related to stent-graft deployment. A proximal landing zone analysis showed frequently elliptical true lumens. The area-derived diameters tended to underestimate the size in highly elliptical lumens, whereas the major axis more closely corresponded to the selected device diameter. CONCLUSION: TEVAR for retrograde type A aortic dissection is a feasible strategy with acceptable mid-to long-term outcomes in selected patients. Precise preoperative anatomical assessment and appropriate device sizing are essential to prevent complications. Evaluating the true lumen morphology at the proximal landing zone is critical for optimal device selection.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Division of Thoracic and Cardiovascular Surgery, Niigata University Graduate School of Medical and Dental Sciences, Niigata City, Niigata, Japan.
- Division of Thoracic and Cardiovascular Surgery, Niigata University Graduate School of Medical and Dental Sciences, Niigata City, Niigata, Japan. Electronic address: t_okamo@pop16.odn.ne.jp.
Zitieren
APA
Onishi, R., Okamoto, T., Shimada, A., Takamatsu, Y., Okoshi, Y., Suzuki, S., Okubo, Y., Nagasawa, A., Domae, K., Mishima, T., Shiraishi, S., & Tsuchida, M. (2026). Thoracic Endovascular Repair for Retrograde Type A Aortic Dissection: True Lumen Device Sizing. Annals of Vascular Surgery. https://doi.org/10.1016/j.avsg.2026.06.016
Vancouver
Onishi R, Okamoto T, Shimada A, Takamatsu Y, Okoshi Y, Suzuki S, et al. Thoracic Endovascular Repair for Retrograde Type A Aortic Dissection: True Lumen Device Sizing. Annals of Vascular Surgery. 2026. doi:10.1016/j.avsg.2026.06.016
BibTeX
@article{Onishi2026,
author = {Onishi, Ryo and Okamoto, Takeshi and Shimada, Atsuki and Takamatsu, Yuki and Okoshi, Yuki and Suzuki, Syuhei and Okubo, Yuka and Nagasawa, Ayako and Domae, Keitaro and Mishima, Takehito and Shiraishi, Shuichi and Tsuchida, Masanori},
title = {Thoracic Endovascular Repair for Retrograde Type A Aortic Dissection: True Lumen Device Sizing},
journal = {Annals of Vascular Surgery},
year = {2026},
doi = {10.1016/j.avsg.2026.06.016}
}
EUVIMED