EUVIMEDEUVIMED entdecken
BeobachtungsstudieOpen Access · CC BY-NC 4.0

Increased Aortic Angulation in Transcatheter Aortic Valve Implantation—Still a Challenging Anatomy?

Emre Polat iD, Arianna Fortunato, Lena Schemet, Sarah Friedrich-Welz, Anton Tomsic, Mohamed Amer, Evaldas Girdauskas iD, Tamer Owais

Interdisciplinary CardioVascular and Thoracic Surgery · 2025

DOI: 10.1093/icvts/ivaf281 ↗

Kurz gefasst

Beobachtungsstudie in der Zeitschrift Interdisciplinary CardioVascular and Thoracic Surgery, 2025. Verfasst von Emre Polat und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Cardiothoracic Surgery, Augsburg University Hospital, 86156 Augsburg, Germany. Hauptthemen laut MEDLINE: Transcatheter Aortic Valve Replacement, Aortic Valve Stenosis, Aortic Valve. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

Increased aortic angulation (AA) is anatomically challenging during transcatheter aortic valve implantation (TAVI) and may affect procedural outcomes. This study evaluates the clinical and procedural impact of AA in contemporary TAVI procedures.

Methods

This retrospective single-centre observational study included 509 consecutive patients undergoing transfemoral TAVI between January 2021 and December 2024. The primary end-point was device success according to VARC-3 criteria. Secondary endpoints included technical success, early safety at 30 days, procedural time, fluoroscopy time, contrast volume, paravalvular regurgitation (PVR), and permanent pacemaker implantation (PPI). Multivariable logistic and linear regression models were used to assess the association between AA (in degrees) and clinical outcomes. Receiver operating characteristic (ROC) and spline regression analyses were used to evaluate potential threshold effects.

Results

Device success at discharge was achieved in 89.4% (455/509) of patients, technical success in 96.3% (490/509), and early safety at 30 days in 75.6% (385/509). Aortic angulation did not significantly influence device success (adjusted odds ratio [aOR]: 0.974, 95% CI: 0.938-1.012, P = .175), technical success (aOR 1.034; 95% CI 0.980-1.091; P = .22), or early safety (aOR: 0.994, 95% CI: 0.968-1.020, P = .633). Similarly, no association was observed between AA and PPI (aOR 1.016; 95% CI 0.984-1.050; P = .34) and PVR. However, AA significantly correlated with increased fluoroscopy times (coefficient: 0.073, SE: 0.026; P = .006) and greater contrast usage (coefficient: 0.406, SE: 0.194; P = .037).

Conclusions

While higher AA increased procedural imaging demand, it did not adversely affect device performance or clinical safety outcomes after TAVI. Importantly, outcomes remained consistent across prosthesis types.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Transcatheter Aortic Valve ReplacementAortic Valve StenosisAortic ValveHumansMaleFemaleRetrospective StudiesAged, 80 and overAgedTreatment OutcomeHeart Valve ProsthesisRisk FactorsPostoperative Complications

Stichwörter der Autor:innen

aortic valveaortic valve stenosisheart valvetranscatheter aortic valve implantation

Autor:innen und Institutionen

  • Department of Cardiothoracic Surgery, Augsburg University Hospital, 86156 Augsburg, Germany.
  • Department of Mathematical Statistics and Artificial Intelligence in Medicine, University of Augsburg, 86156 Augsburg, Germany.
  • Center for Advanced Analytics and Predictive Sciences (CAAPS), University of Augsburg, 86156 Augsburg, Germany.
  • Department of Cardiac Surgery, Heart Center Helios Wuppertal, University of Witten/Herdecke, 42117 Wuppertal, Germany.

ORCID-Profile: Emre Polat, Evaldas Girdauskas

Zitieren

APA

Polat, E., Fortunato, A., Schemet, L., Friedrich-Welz, S., Tomsic, A., Amer, M., Girdauskas, E., & Owais, T. (2025). Increased Aortic Angulation in Transcatheter Aortic Valve Implantation—Still a Challenging Anatomy?. Interdisciplinary CardioVascular and Thoracic Surgery. https://doi.org/10.1093/icvts/ivaf281

Vancouver

Polat E, Fortunato A, Schemet L, Friedrich-Welz S, Tomsic A, Amer M, et al. Increased Aortic Angulation in Transcatheter Aortic Valve Implantation—Still a Challenging Anatomy?. Interdisciplinary CardioVascular and Thoracic Surgery. 2025. doi:10.1093/icvts/ivaf281

BibTeX
@article{Polat2025,
  author = {Polat, Emre and Fortunato, Arianna and Schemet, Lena and Friedrich-Welz, Sarah and Tomsic, Anton and Amer, Mohamed and Girdauskas, Evaldas and Owais, Tamer},
  title = {Increased Aortic Angulation in Transcatheter Aortic Valve Implantation—Still a Challenging Anatomy?},
  journal = {Interdisciplinary CardioVascular and Thoracic Surgery},
  year = {2025},
  doi = {10.1093/icvts/ivaf281}
}
Kostenlos starten →