Coherence-Weighted Synthetic Focusing Applied to Photoacoustic Imaging Using a High-Frequency Annular-Array Transducer
Ultrasonic Imaging · 2016-01 · 38 (1) · 32-43
DOI: 10.1177/0161734615583981 ↗Kurz gefasst
Fachartikel in der Zeitschrift Ultrasonic Imaging, online erschienen am 28.04.2015. Verfasst von Parag V Chitnis und 5 weiteren Autor:innen. Beteiligte Einrichtung: Riverside Research, F.L. Lizzi Center for Biomedical Engineering, New York, NY, USA pchitnis@gmu.edu. Hauptthemen laut MEDLINE: Signal Processing, Computer-Assisted, Transducers. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIBIB NIH HHS.
Abstract (Originalsprache)
This paper presents an adaptive synthetic-focusing scheme that, when applied to photoacoustic (PA) data acquired using an annular array, improves focusing across a greater imaging depth and enhances spatial resolution. The imaging system was based on a 40-MHz, 5-element, annular-array transducer with a focal length of 12 mm and an 800-µm diameter hole through its central element to facilitate coaxial delivery of 532-nm laser. The transducer was raster-scanned to facilitate 3D acquisition of co-registered ultrasound and PA image data. Three synthetic-focusing schemes were compared for obtaining PA A-lines for each scan location: delay-and-sum (DAS), DAS weighted with a coherence factor (DAS + CF), and DAS weighted with a sign-coherence factor (DAS + SCF). Bench-top experiments that used an 80-µm hair were performed to assess the enhancement provided by the two coherence-based schemes. Both coherence-based schemes increased the signal-to-noise ratio by approximately 10 dB. When processed using the DAS-only scheme, the lateral dimension of the hair in a PA image with 20 dB dynamic range was between 300 µm and 1 mm for imaging depth ranging from 8 to 20 mm. In comparison, the DAS + CF scheme resulted in a lateral dimension of 200 to 450 µm over the same range. The DAS + SCF synthetic focusing further improved the smallest-resolvable dimension, which was between 150 and 400 µm over the same range of imaging depth. When used on PA data obtained from a 12-day-old mouse embryo, the DAS + SCF processing improved visualization of neurovasculature.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Riverside Research, F.L. Lizzi Center for Biomedical Engineering, New York, NY, USA pchitnis@gmu.edu.
- Skirball Institute of Biomolecular Medicine, NYU School of Medicine, New York, NY, USA.
- Riverside Research, F.L. Lizzi Center for Biomedical Engineering, New York, NY, USA.
Förderung
- NIBIB NIH HHS
Zitieren
APA
Chitnis, P. V., Aristizábal, O., Filoux, E., Sampathkumar, A., Mamou, J., & Ketterling, J. A. (2016). Coherence-Weighted Synthetic Focusing Applied to Photoacoustic Imaging Using a High-Frequency Annular-Array Transducer. Ultrasonic Imaging, 38(1), 32-43. https://doi.org/10.1177/0161734615583981
Vancouver
Chitnis PV, Aristizábal O, Filoux E, Sampathkumar A, Mamou J, Ketterling JA. Coherence-Weighted Synthetic Focusing Applied to Photoacoustic Imaging Using a High-Frequency Annular-Array Transducer. Ultrasonic Imaging. 2016;38(1):32-43. doi:10.1177/0161734615583981
BibTeX
@article{Chitnis2016,
author = {Chitnis, Parag V and Aristizábal, Orlando and Filoux, Erwan and Sampathkumar, Ashwin and Mamou, Jonathan and Ketterling, Jeffrey A},
title = {Coherence-Weighted Synthetic Focusing Applied to Photoacoustic Imaging Using a High-Frequency Annular-Array Transducer},
journal = {Ultrasonic Imaging},
year = {2016},
volume = {38},
number = {1},
pages = {32--43},
doi = {10.1177/0161734615583981}
}
EUVIMED