Experimental investigation of uniform blast loaded glass-fibre reinforced polymer panels with two and four sided constrained boundaries
Journal of Composite Materials · 18.11.2026
DOI: 10.1177/00219983261504921 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Composite Materials, online erschienen am 18.11.2026. Verfasst von Shivasi Mashau und 4 weiteren Autor:innen. Die Arbeit nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National Research Foundation.
Abstract (Originalsprache)
The influence of boundary conditions on the response of composite panels subjected to air-blast loading is explored. Glass-fibre reinforced polymer laminate panels were subjected to approximately uniform explosive blast loads. The uniformity was demonstrated using a finite element model which was validated by comparing peak over-pressures to predictions from a recognised approach. The experimental results showed the damage evolution of panels with differing boundary conditions, that is, constrained either on all four sides (CCCC) or only on two opposite sides (CFCF). The transient deformation was obtained using photography and digital image correlation techniques. The boundary type affected the shape and magnitude of deformation, with CFCF-panels exhibiting a greater centre displacement. Inspection of the panels revealed that damage was initiated along the clamped edges in the form of matrix damage on the compressive face. The threshold for damage initiation was lower for the CCCC than the CFCF boundary conditions. Delamination was initiated at a lower impulse in the CCCC-panels and constituted a larger area in the CCCC-panels than the CFCF-panels for equivalent impulse. The CFCF-panels exhibited more matrix damage and through thickness cracking. CFCF-panels exhibited distinctive damage modes, whereas CCCC-panels enabled the load to be distributed along four sides (leading to greater delamination but lower out-of-plane displacements). The importance of accurately determining structural boundary conditions when considering the transient response and damage of fibre reinforced polymer composite laminate panels under blast loading was demonstrated.
Förderung
- National Research Foundation
Zitieren
APA
Mashau, S., Klemperer, C. J. V., Yuen, S. C. K., Langdon, G. S., & Gabriel, S. (2026). Experimental investigation of uniform blast loaded glass-fibre reinforced polymer panels with two and four sided constrained boundaries. Journal of Composite Materials. https://doi.org/10.1177/00219983261504921
Vancouver
Mashau S, Klemperer CJV, Yuen SCK, Langdon GS, Gabriel S. Experimental investigation of uniform blast loaded glass-fibre reinforced polymer panels with two and four sided constrained boundaries. Journal of Composite Materials. 2026. doi:10.1177/00219983261504921
BibTeX
@article{Mashau2026,
author = {Mashau, Shivasi and Klemperer, Christopher J. von and Yuen, Steeve Chung Kim and Langdon, Genevieve S. and Gabriel, Sherlyn},
title = {Experimental investigation of uniform blast loaded glass-fibre reinforced polymer panels with two and four sided constrained boundaries},
journal = {Journal of Composite Materials},
year = {2026},
doi = {10.1177/00219983261504921}
}
EUVIMED