Mechanical behaviour of glass fibre-reinforced polymer-reinforced steel–polyvinyl alcohol hybrid fibre concrete columns
Proceedings of the Institution of Civil Engineers - Structures and Buildings · 05.08.2026 · 179 (7) · 757-774
DOI: 10.1680/jstbu.25.00183 ↗Kurz gefasst
Fachartikel in der Zeitschrift Proceedings of the Institution of Civil Engineers - Structures and Buildings, online erschienen am 27.05.2026. Verfasst von Liangli Xiao und 2 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: National Natural Science Fundation of China, Natural Science Fundation of Hubei Province, Construction Technology Programme of Hubei Province.
Abstract (Originalsprache)
This study aims to elucidate the synergistic action of steel and polyvinyl alcohol (PVA) hybrid fibres in glass fibre-reinforced polymer (GFRP)-reinforced concrete columns and to develop a reliable prediction model for axial compressive capacity. Axial compression tests were performed on nine specimens: eight hybrid fibre-reinforced GFRP concrete columns with varied fibre dosages and one conventional steel-reinforced control column. Failure modes, load–displacement behaviour and strain responses of longitudinal reinforcement, transverse reinforcement and concrete were compared across mixtures. Fibre-free GFRP columns exhibited sudden, brittle failure. Steel fibres primarily enhanced ultimate capacity; at 1.4% and 0.8% volume fractions, ultimate loads increased by 17.1% and 13.7%, respectively, relative to the steel control and by 24.7% and 21.1%, respectively, relative to the fibre-free column. However, excessive steel fibre content (>1.4%) caused poor dispersion and weaker fibre–matrix bonding, reducing reinforcement efficiency, axial displacement at peak load and overall ductility. In contrast, PVA fibres improved post-peak deformation and energy absorption, and hybridisation provided stable, balanced performance gains. Based on the experimental data set, relevant design codes and micromechanical interpretation, an optimised ultimate-capacity formula is proposed, showing good agreement with the measured results. The model offers a practical basis for design of hybrid-fibre GFRP columns.
Förderung
- National Natural Science Fundation of China
- Natural Science Fundation of Hubei Province
- Construction Technology Programme of Hubei Province
Zitieren
APA
Xiao, L., Tan, Z., & Sun, F. (2026). Mechanical behaviour of glass fibre-reinforced polymer-reinforced steel–polyvinyl alcohol hybrid fibre concrete columns. Proceedings of the Institution of Civil Engineers - Structures and Buildings, 179(7), 757-774. https://doi.org/10.1680/jstbu.25.00183
Vancouver
Xiao L, Tan Z, Sun F. Mechanical behaviour of glass fibre-reinforced polymer-reinforced steel–polyvinyl alcohol hybrid fibre concrete columns. Proceedings of the Institution of Civil Engineers - Structures and Buildings. 2026;179(7):757-774. doi:10.1680/jstbu.25.00183
BibTeX
@article{Xiao2026,
author = {Xiao, Liangli and Tan, Zhiwei and Sun, Fanqiang},
title = {Mechanical behaviour of glass fibre-reinforced polymer-reinforced steel–polyvinyl alcohol hybrid fibre concrete columns},
journal = {Proceedings of the Institution of Civil Engineers - Structures and Buildings},
year = {2026},
volume = {179},
number = {7},
pages = {757--774},
doi = {10.1680/jstbu.25.00183}
}
EUVIMED