EUVIMEDEuropean Health Evidence
Uhr 7/7Sources Journal Tree
Easy Demo

Lokaler Crossref-Datenbestand · journal-article

A 3-year review of external proficiency testing, evaluating analytical performance and diagnostic accuracy of HELIOS in detecting autoimmune disorders.

Nayab Zehra, Asif Loya, Hiba Asif, Mudassar Hussain, Hina Maqbool, Umer Nisar

Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · 2026

Vollständiger Abstract

Worum geht es in dieser Arbeit?

Objective: To assess the analytical performance and diagnostic accuracy of an automated analyzer HELIOS in external proficiency testing for diagnosing autoimmune disorders based on antinuclear antibody (ANA) images and titer values. Methods: Total 09 CAP shipments over the period of 03 years were included in our study, comprising of 05 samples in each shipment making a total of 45 samples. All samples were analyzed on HELIOS by the technique of Indirect Immunofluorescence (IFA) having built-in library for ANA image comparison and end point titer estimation. Results: The data showed that there was 100% agreement with the positivity and negativity of the PT samples in detecting autoimmune disorders, however, for ANA pattern agreement, it was an average of 90.3% compared to peer mean. The most frequent ANA pattern in all 3 years was nuclear homogenous (40%) followed by nuclear speckled (32%). However, for end-point titer, there is a huge difference of mutual agreement with the PT peer group showing the lowest harmony of 35.3% in 2022 which was reported with titer of 5120, however peer group reported titer was ≤ 640. Thus, the analyzer has a limitation in evaluating end point titer and it should always be critically evaluated by the pathologist before final approval. Conclusion: HELIOS has an acceptable performance in detecting autoimmune disorders and ANA pattern identification, however, for end-point titer, there were many variations for which manual dilutions should be done in routine for accurate analysis of results. Key Words: Autoimmune disorders, External Proficiency testing, HELIOS, Analytical Performance.

Bibliografischer Nachweis

Publikationsdaten

Autor:innen
Nayab Zehra, Asif Loya, Hiba Asif, Mudassar Hussain, Hina Maqbool, Umer Nisar
Quelle
Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
Publikation
2026-01-01
Band / Ausgabe
Nicht angegeben
Seiten
Nicht angegeben
ISSN / ISBN
0004-5632, 1758-1001
Zitationen
0 laut Crossref
Referenzen
0 hinterlegt

Zitieren

Zitierfähiger Nachweis

Nayab Zehra, Asif Loya, Hiba Asif, Mudassar Hussain, Hina Maqbool, Umer Nisar (2026). A 3-year review of external proficiency testing, evaluating analytical performance and diagnostic accuracy of HELIOS in detecting autoimmune disorders. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. https://doi.org/10.1177/00045632261488247
RIS BibTeX CSL-JSON

Kontext

Themen, Förderung und Nutzung

Lizenzhinweise: Lizenz 1