Myopia Prescription Based on Smartphone App: A Feasibility Study in Africa
Translational Vision Science & Technology · 09.02.2026 · 15 (2) · 13
DOI: 10.1167/tvst.15.2.13 ↗Kurz gefasst
Fachartikel in der Zeitschrift Translational Vision Science & Technology, erschienen am 09.02.2026. Verfasst von Gang Luo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Schepens Eye Research Institute of Mass Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA. Hauptthemen laut MEDLINE: Smartphone, Prescriptions, Myopia, Refraction, Ocular. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NEI NIH HHS.
Abstract (Originalsprache)
Purpose
Uncorrected refractive error (URE) is the leading cause of vision impairment, especially in rural, underserved areas. We previously evaluated the accuracy of a smartphone app for measuring spherical equivalent refraction. In this study, we evaluated the benefits of vision correction based on the prescription given by the app.
Methods
The app estimates myopic refractive error by measuring the far point distances for reading 20/20 Tumbling E letters. Trial lenses rounded to 0.25 diopter (D) were fitted to 100 patients (myopic refractive error, astigmatism < 1.5 D) visiting MCM Eye Unit in Addis Ababa, Ethiopia. The age range of the participants was 10 to 68 years (mean = 31.3 ± 13.0 years). The refraction measurement and visual acuity (VA) tests were all performed without cycloplegia.
Results
The range of spherical equivalent refractive error was -0.5 D to -6 D (interquartile range [IQR] = -2.25 D to -0.95 D), and the range of astigmatism was 0 to -1.25 D (IQR = -0.5 D to 0 D), according to subjective refraction performed by a study optometrist. On average, the uncorrected VA of the 200 eyes was 0.57 ± 0.32 logMAR. With the spherical equivalent correction based on the refraction app, their VA was improved significantly to 0.03 ± 0.09 logMAR-more than 5 lines of improvement, on average.
Conclusions
This study indicates that using the app to determine the spherical equivalent prescription for vision correction addresses the URE problem, whereas its effect for prominent astigmatism is yet to be evaluated. Translational Relevance: This approach, which requires minimal training, has potential in fighting avoidable blindness in underserved areas lacking optometry services, such as remote Sub-Saharan Africa.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Schepens Eye Research Institute of Mass Eye and Ear, Department of Ophthalmology, Harvard Medical School, Boston, MA, USA.
- MCM Eye Unit, MyungSung Christian Medical Center (MCM) General Hospital and MyungSung Medical College, Addis Ababa, Ethiopia.
- Berhan Public Health and Eye Care Consultancy, Addis Ababa, Ethiopia.
- Department of Global Health and Social Medicine, Harvard Medical School, Boston, MA, USA.
- Sight for Souls, Bellevue, WA, USA.
- Department of Ophthalmology, Addis Ababa University School of Medicine, Addis Ababa, Ethiopia.
Förderung
- NEI NIH HHS
Zitieren
APA
Luo, G., Tekle, B., Pundlik, S., Lee, C. Y., Abashawl, A., & Kempen, J. H. (2026). Myopia Prescription Based on Smartphone App: A Feasibility Study in Africa. Translational Vision Science & Technology, 15(2), 13. https://doi.org/10.1167/tvst.15.2.13
Vancouver
Luo G, Tekle B, Pundlik S, Lee CY, Abashawl A, Kempen JH. Myopia Prescription Based on Smartphone App: A Feasibility Study in Africa. Translational Vision Science & Technology. 2026;15(2):13. doi:10.1167/tvst.15.2.13
BibTeX
@article{Luo2026,
author = {Luo, Gang and Tekle, Biruk and Pundlik, Shrinivas and Lee, Chen-Yuan and Abashawl, Aida and Kempen, John H},
title = {Myopia Prescription Based on Smartphone App: A Feasibility Study in Africa},
journal = {Translational Vision Science & Technology},
year = {2026},
volume = {15},
number = {2},
pages = {13},
doi = {10.1167/tvst.15.2.13}
}