EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Postoperative-Only Estimation of Implanted Intraocular Lens Power Using a Closed-Form Thick-Lens Model With Patient-Specific Predictive Intervals

Damien Gatinel, Guillaume Debellemanière, Alain Saad, Jacques Malet

Translational Vision Science & Technology · 02.11.2026 · 15 (11) · 2

DOI: 10.1167/tvst.15.11.2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Translational Vision Science & Technology, erschienen am 02.11.2026. Verfasst von Damien Gatinel und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anterior Segment and Refractive Surgery, Rothschild Foundation Hospital, Paris, France. Hauptthemen laut MEDLINE: Lenses, Intraocular, Lens Implantation, Intraocular, Refraction, Ocular, Pseudophakia. Die Arbeit nennt 23 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To estimate labeled implanted intraocular lens (IOL) power from postoperative measurements using a closed-form thick-lens model and provide patient-specific predictive intervals.

Methods

We included non-toric pseudophakic eyes with postoperative axial length, aqueous depth, central corneal thickness, total corneal power, and manifest refraction. A paraxial thick-lens equation was analytically inverted using axial length, aqueous depth plus central corneal thickness, total corneal power, and spherical equivalent. The total-corneal-power zone was selected in the training set, followed by patient-level train/test evaluation. Predictions were assessed continuously and after rounding to 0.50-D inventory steps. Predictive intervals used closed-form sensitivities, first-order variance propagation, and training-set calibration.

Results

The cohort comprised 170 eyes from 109 patients, and the held-out test set comprised 32 eyes from 22 patients. The 4-mm total-corneal-power zone performed best. Continuous test predictions had a mean absolute error of 0.397 D and root mean square error of 0.509 D, and 65.6% were within ±0.50 D. After 0.50-D rounding, mean absolute error was 0.391 D and root mean square error was 0.566 D, and 75.0% were within ±0.50 D. Calibrated 95% predictive intervals covered 31 of 32 test eyes (96.9%); patient-level coverage was 21 of 22 (95.5%), with a mean interval width of 2.238 D.

Conclusions

Postoperative-only thick-lens estimation provides a consistency check against recorded IOL labels but is not precise enough to identify small discrepancies confidently. Translational Relevance: When operative records are missing, the method offers a physically grounded label-consistency check with explicit uncertainty.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Lenses, IntraocularLens Implantation, IntraocularRefraction, OcularPseudophakiaOptics and PhotonicsHumansPostoperative PeriodFemaleAgedMaleCorneaMiddle AgedAxial Length, Eye

Autor:innen und Institutionen

  • Department of Anterior Segment and Refractive Surgery, Rothschild Foundation Hospital, Paris, France.

Zitieren

APA

Gatinel, D., Debellemanière, G., Saad, A., & Malet, J. (2026). Postoperative-Only Estimation of Implanted Intraocular Lens Power Using a Closed-Form Thick-Lens Model With Patient-Specific Predictive Intervals. Translational Vision Science & Technology, 15(11), 2. https://doi.org/10.1167/tvst.15.11.2

Vancouver

Gatinel D, Debellemanière G, Saad A, Malet J. Postoperative-Only Estimation of Implanted Intraocular Lens Power Using a Closed-Form Thick-Lens Model With Patient-Specific Predictive Intervals. Translational Vision Science & Technology. 2026;15(11):2. doi:10.1167/tvst.15.11.2

BibTeX
@article{Gatinel2026,
  author = {Gatinel, Damien and Debellemanière, Guillaume and Saad, Alain and Malet, Jacques},
  title = {Postoperative-Only Estimation of Implanted Intraocular Lens Power Using a Closed-Form Thick-Lens Model With Patient-Specific Predictive Intervals},
  journal = {Translational Vision Science & Technology},
  year = {2026},
  volume = {15},
  number = {11},
  pages = {2},
  doi = {10.1167/tvst.15.11.2}
}
Kostenlos starten →