Variations in Corneal Refractive Change Region After Orthokeratology Lens Wear
Translational Vision Science & Technology · 02.11.2026 · 15 (11) · 1
DOI: 10.1167/tvst.15.11.1 ↗Kurz gefasst
Fachartikel in der Zeitschrift Translational Vision Science & Technology, erschienen am 02.11.2026. Verfasst von Hailiang Zhao und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Beijing Longfu Hospital, Beijing, People's Republic of China. Hauptthemen laut MEDLINE: Orthokeratologic Procedures, Myopia, Refraction, Ocular, Cornea. Die Arbeit nennt 27 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).
Abstract (Originalsprache)
Purpose
This study analyzed 1-year longitudinal variations in the corneal refractive change (CRC) region after orthokeratology (Ortho-K) lens wear between vision shaping treatment (VST) and corneal refractive therapy (CRT) designs.
Methods
A retrospective analysis was conducted on 148 patients with myopia (148 eyes) treated with Ortho-K lenses for 12 months at Beijing Tongren Hospital's myopia clinic from June 2020 to December 2022. Participants were divided into two groups: group A (74 eyes) who wore VST design Ortho-K lens, and group B (74 eyes) who wore CRT design lens. Data from the right eyes were collected. Measurements included tangential corneal topography maps, which were converted into refractive power maps to calculate the area, height, and volume of the CRC region. Measurements were taken at baseline and during follow-ups after lens wear. Changes in magnitude of the CRC region were analyzed for different Ortho-K lens designs.
Results
No statistically significant difference in the height of the CRC region was observed between group A and group B on the first day of lens wear (P > 0.05). However, significant differences emerged at 1 month, 3 months, 6 months, and 1 year of wear (P 0.05). The area of the CRC region decreased significantly by month 1 in the VST group while slightly rising in the CRT group, with no significant post-1-month fluctuations across the 12-month follow-up. The volume of the CRC region rose rapidly and then plateaued by 1 month. The axial length increased by 0.17 mm and 0.19 mm for group A and group B, respectively, after 6 months of lens wear. After 1 year, the axial elongation values were 0.26 mm and 0.28 mm for the 2 groups, with no statistically significant intergroup difference observed at either follow-up time point (P > 0.05).
Conclusions
Orthokeratology induces measurable changes in the height and volume of the CRC region. Both parameters are important for evaluating myopia control outcomes, and our findings provide guidance for clinical lens selection. Translational Relevance: A mathematical model was applied to characterize dynamic corneal defocus changes. The results enable precise clinical practice, such as personalized lens configuration, efficacy prediction, and stratified management for orthokeratology patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Ophthalmology, Beijing Longfu Hospital, Beijing, People's Republic of China.
- Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University, Beijing, People's Republic of China.
- Beijing Tongren Eye Center, Beijing Institute of Ophthalmology, Beijing Tongren Hospital, Capital Medical University, Beijing Key Laboratory of Ophthalmology and Visual Sciences, National Engineering Research Center for…
Zitieren
APA
Zhao, H., Zhou, F., & Song, H. (2026). Variations in Corneal Refractive Change Region After Orthokeratology Lens Wear. Translational Vision Science & Technology, 15(11), 1. https://doi.org/10.1167/tvst.15.11.1
Vancouver
Zhao H, Zhou F, Song H. Variations in Corneal Refractive Change Region After Orthokeratology Lens Wear. Translational Vision Science & Technology. 2026;15(11):1. doi:10.1167/tvst.15.11.1
BibTeX
@article{Zhao2026,
author = {Zhao, Hailiang and Zhou, Fengchao and Song, Hongxin},
title = {Variations in Corneal Refractive Change Region After Orthokeratology Lens Wear},
journal = {Translational Vision Science & Technology},
year = {2026},
volume = {15},
number = {11},
pages = {1},
doi = {10.1167/tvst.15.11.1}
}
EUVIMED