EUVIMEDEUVIMED entdecken
Vergleichsstudie

Comparison of two designs of orthokeratology lenses with smaller back optic zone diameters in myopia control

Sili Jing iD, Hong Yan, Yaqun Wan

Ophthalmic and Physiological Optics · 2025

DOI: 10.1111/opo.13551 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Ophthalmic and Physiological Optics, 2025. Verfasst von Sili Jing und 2 weiteren Autor:innen. Beteiligte Einrichtung: Shaanxi Eye Hospital, Xi'an People's Hospital (Xi'an Fourth Hospital), Affiliated People's Hospital of Northwest University, Xi'an, China. Hauptthemen laut MEDLINE: Orthokeratologic Procedures, Refraction, Ocular, Myopia, Visual Acuity. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 37 Literaturangaben. Gefördert von: Xian People's Hospital (Xi'an Fourth Hospital), National Natural Science Foundation of China.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The aim of this study was to compare and evaluate the efficacy and safety of corneal refractive therapy (CRT) and vision shaping treatment (VST) orthokeratology lenses with smaller back optical zone diameters (BOZD) in controlling myopia progression.

Methods

This retrospective study was completed from June 2019 to June 2024. A total of 1612 right eyes of myopic patients aged 8–16 years were included for analysis, and samples were categorised into four groups based on the orthokeratology lenses and their BOZD: CRT (BOZD = 6.0 mm), small BOZD CRT (CRT‐S; BOZD = 5.0 mm), VST (BOZD = 6.2 mm) and small BOZD VST (VST‐S, BOZD = 5.2 mm). Uncorrected visual acuity (UCVA), flat keratometry (Kf), axial length (AL) horizontal treatment zone diameter (TZD), refractive sphere (DS), refractive cylinder (DC), spherical equivalent (SE) and incidence of corneal injury were measured.

Results

Follow‐up assessments were conducted until the end of the second year. The TZD of the VST‐S group (1.93 ± 0.27) was significantly smaller than the CRT‐S group (2.14 ± 0.21) ( p < 0.001). The increase in AL in the VST‐S group (0.33 ± 0.40) was significantly lower than the CRT‐S group (0.44 ± 0.21) ( p < 0.001). The changes in DS (−1.47 ± 0.33 vs. −1.39 ± 0.48, p = 0.01) and SE (−1.06 ± 0.77 vs. −1.62 ± 0.52, p < 0.001) in the VST‐S group were significantly smaller than for the CRT‐S group. No significant differences were identified in DC, UCVA and Kf changes across groups. Only a few participants exhibited corneal staining or erosion, with no significant difference between groups.

Conclusions

The myopia control effect of the VST‐S lenses was significantly superior to the CRT‐S lenses. Clinicians should interpret these findings cautiously when choosing smaller BOZD lenses for myopia control.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Orthokeratologic ProceduresRefraction, OcularMyopiaVisual AcuityContact LensesHumansRetrospective StudiesChildAdolescentFemaleMaleCorneaFollow-Up StudiesCorneal TopographyTreatment OutcomeEquipment Design

Stichwörter der Autor:innen

back optical zone diametermyopiaorthokeratology

Autor:innen und Institutionen

  • Shaanxi Eye Hospital, Xi'an People's Hospital (Xi'an Fourth Hospital), Affiliated People's Hospital of Northwest University, Xi'an, China.

ORCID-Profile: Sili Jing

Förderung

  • Xian People's Hospital (Xi'an Fourth Hospital)
  • National Natural Science Foundation of China

Zitieren

APA

Jing, S., Yan, H., & Wan, Y. (2025). Comparison of two designs of orthokeratology lenses with smaller back optic zone diameters in myopia control. Ophthalmic and Physiological Optics. https://doi.org/10.1111/opo.13551

Vancouver

Jing S, Yan H, Wan Y. Comparison of two designs of orthokeratology lenses with smaller back optic zone diameters in myopia control. Ophthalmic and Physiological Optics. 2025. doi:10.1111/opo.13551

BibTeX
@article{Jing2025,
  author = {Jing, Sili and Yan, Hong and Wan, Yaqun},
  title = {Comparison of two designs of orthokeratology lenses with smaller back optic zone diameters in myopia control},
  journal = {Ophthalmic and Physiological Optics},
  year = {2025},
  doi = {10.1111/opo.13551}
}
Kostenlos starten →