EUVIMEDEUVIMED entdecken
QuerschnittstudieOpen Access · CC BY-NC-ND 4.0

Influence of Corneal Diameter on Corneal Biomechanics and Biometry in Chinese Patients: A Cross-Sectional Study

Huanmin Cheng, Qiwei Li, Fan Yang, Emmanuel Eric Pazo, Jonathan E Moore, Zhanglin Liu, Ming Sun, Shaozhen Zhao, Yue Huang

Translational Vision Science & Technology · 2025

DOI: 10.1167/tvst.14.11.34 ↗

Kurz gefasst

Querschnittstudie in der Zeitschrift Translational Vision Science & Technology, 2025. Verfasst von Huanmin Cheng und 8 weiteren Autor:innen. Beteiligte Einrichtung: Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and S…. Hauptthemen laut MEDLINE: Biometry, Cornea, Keratoconus. Die Arbeit nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The purpose of this study was to investigate the influence of corneal diameter (CD) on corneal biomechanics and biometry parameters to allow more accurate evaluation of refractive surgery patients.

Methods

In this cross-sectional study, 203 Chinese participants were categorized into four groups based on CD (group A = CD ≤11.1 mm, group B = CD = 11.2-11.5 mm, group C = CD = 11.6-12 mm, and group D = CD >12.0 mm). Data collected included age, gender, intraocular pressure, spherical equivalent, and parameters from the Pentacam and Corvis ST. Statistical analysis was performed using SPSS software.

Results

The study included 203 eyes. For the Pentacam examination, corneal curvature, thinnest pachymetry (TP), back elevations (BEs), corneal elevation difference (front and back), pachymetry progression indices (PPIs), index of surface variance (ISV), keratoconus percentage index (KISA%), and most of the Belin/Ambrósio Enhanced Ectasia Display (BAD) parameters were negatively correlated with CD (linear regression analysis, P < 0.05). The abnormal rate of Pentacam parameters in the CD ≤11.1 mm group was higher than other groups. For Corvis ST, CD was positively correlated with peak distance (PD) and Ambrósio relational thickness to the horizontal profile (Arth), but negatively correlated with tomographic and biomechanical index (TBI) and Corvis biomechanical index (CBI; linear regression analysis, P < 0.05). The CD ≤11.1 mm group demonstrated the highest CBI and TBI values, although these parameters remained within the normal range.

Conclusions

Corneal diameter significantly influences Pentacam and Corvis ST parameters, particularly on BE, BAD-D, PPIs, CBI, and TBI. Translational Relevance: Incorporating corneal diameter into preoperative screening may help improve the specificity of keratoconus detection and reduce unnecessary exclusion of eligible refractive surgery candidates with small corneas.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

BiometryCorneaKeratoconusAdolescentAdultFemaleHumansMaleMiddle AgedYoung AdultBiomechanical PhenomenaChinaCorneal PachymetryCorneal TopographyCross-Sectional StudiesIntraocular PressureEast Asian People

Autor:innen und Institutionen

  • Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin,…
  • Cathedral Eye Clinic, Belfast, Northern Ireland, UK.

Zitieren

APA

Cheng, H., Li, Q., Yang, F., Pazo, E. E., Moore, J. E., Liu, Z., Sun, M., Zhao, S., & Huang, Y. (2025). Influence of Corneal Diameter on Corneal Biomechanics and Biometry in Chinese Patients: A Cross-Sectional Study. Translational Vision Science & Technology. https://doi.org/10.1167/tvst.14.11.34

Vancouver

Cheng H, Li Q, Yang F, Pazo EE, Moore JE, Liu Z, et al. Influence of Corneal Diameter on Corneal Biomechanics and Biometry in Chinese Patients: A Cross-Sectional Study. Translational Vision Science & Technology. 2025. doi:10.1167/tvst.14.11.34

BibTeX
@article{Cheng2025,
  author = {Cheng, Huanmin and Li, Qiwei and Yang, Fan and Pazo, Emmanuel Eric and Moore, Jonathan E and Liu, Zhanglin and Sun, Ming and Zhao, Shaozhen and Huang, Yue},
  title = {Influence of Corneal Diameter on Corneal Biomechanics and Biometry in Chinese Patients: A Cross-Sectional Study},
  journal = {Translational Vision Science & Technology},
  year = {2025},
  doi = {10.1167/tvst.14.11.34}
}
Kostenlos starten →