EUVIMEDEUVIMED entdecken
ValidierungsstudieOpen Access · CC BY 4.0

Validity and reliability of running gait measurement with the ViMove2 system

Rachel Mason iD, Gillian Barry, Gary Hall, Alan Godfrey iD, Samuel Stuart iD

PLOS ONE · 2024

DOI: 10.1371/journal.pone.0312952 ↗

Kurz gefasst

Validierungsstudie in der Zeitschrift PLOS ONE, 2024. Verfasst von Rachel Mason und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne, United Kingdom. Hauptthemen laut MEDLINE: Running, Gait, Wearable Electronic Devices. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Northumbria University, Private Physiotherapy Educational Foundation, Parkinson’s Foundation.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Running biomechanics have traditionally been analysed in laboratory settings, but this may not reflect natural running gait. Wearable technology has the potential to enable precise monitoring of running gait beyond the laboratory. This study aimed to evaluate the analytical validity and intra-session reliability of temporal running gait outcomes measured by the ViMove2 wearable system in healthy adults. Seventy-four healthy adults (43 males, 31 females, aged 18–55 years) wore the inertial device, ViMove2 on the tibia. Participants ran on a treadmill for one minute at various speeds (8, 10, 12, 14km/hr), completed in a standardised shoe (Saucony Guide Runner). Running gait was measured with the ViMove2 wearable and 3D motion capture (Vicon). Temporal running gait outcomes included ground contact time (GCT) and cadence (steps/min). GCT and cadence from the ViMove2 had face validity with expected changes in outcome with different running speeds, but ViMove2 tended to over-estimate GCT, and under-estimate cadence compared to the reference, especially at slower speeds. GCT demonstrated moderate to good agreement to the reference at speeds >10km/hr, but poor agreement at 8km/hr and within female runners. Cadence had moderate to excellent agreement across speeds compared to the reference. GCT and cadence had excellent reliability across speeds, but at 8km/hr GCT had good agreement between trials. Overall, temporal gait outcomes of GCT and cadence can be measured with the ViMove2, but accuracy and reliability are impacted at slow running speeds and within female runners. Future work is needed to clarify sex or speed-dependent corrections to algorithms / outcomes to aid interpretation and application.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

RunningGaitWearable Electronic DevicesHumansFemaleMaleAdultMiddle AgedAdolescentYoung AdultReproducibility of ResultsBiomechanical PhenomenaGait Analysis

Autor:innen und Institutionen

  • Department of Sport, Exercise and Rehabilitation, Northumbria University, Newcastle upon Tyne, United Kingdom.
  • Department of Computer and Information Sciences, Northumbria University, Newcastle upon Tyne, United Kingdom.
  • Department of Neurology, Oregon Health and Science University, Portland, Oregon, United States of America.

ORCID-Profile: Rachel Mason, Alan Godfrey, Samuel Stuart

Förderung

  • Northumbria University
  • Private Physiotherapy Educational Foundation
  • Parkinson’s Foundation

Zitieren

APA

Mason, R., Barry, G., Hall, G., Godfrey, A., & Stuart, S. (2024). Validity and reliability of running gait measurement with the ViMove2 system. PLOS ONE. https://doi.org/10.1371/journal.pone.0312952

Vancouver

Mason R, Barry G, Hall G, Godfrey A, Stuart S. Validity and reliability of running gait measurement with the ViMove2 system. PLOS ONE. 2024. doi:10.1371/journal.pone.0312952

BibTeX
@article{Mason2024,
  author = {Mason, Rachel and Barry, Gillian and Hall, Gary and Godfrey, Alan and Stuart, Samuel},
  title = {Validity and reliability of running gait measurement with the ViMove2 system},
  journal = {PLOS ONE},
  year = {2024},
  doi = {10.1371/journal.pone.0312952}
}
Kostenlos starten →