In Vivo Imaging and Evaluation of Corneal Biomechanics After Corneal Transplantation by Optical Coherence Elastography
Journal of Biophotonics · 2024
DOI: 10.1002/jbio.202400207 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Biophotonics, 2024. Verfasst von Gang Shi und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Mathematics and Physics, University of Science and Technology Beijing, Beijing, China. Hauptthemen laut MEDLINE: Cornea, Elasticity Imaging Techniques, Corneal Transplantation. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 42 Literaturangaben. Gefördert von: the National Key Research and Development Project, China, National Natural Science Foundation of China.
Abstract (Originalsprache)
Postoperative corneal biomechanical evaluation is of great significance in clinical monitoring and management since corneal transplantation is one of the main methods to improve visual function. In this paper, we propose an OCE system based on a small ultrasound transducer to realize the in vivo detection of postoperative corneal elasticity in different directions. It was first validated and analyzed by different agar, and then the elasticity changes in normal cornea and post‐transplant corneal implants and implant beds were further investigated. Compared with normal corneas, the shear wave velocity of the postoperative cornea decreased from 7.42 ± 1.71 m/s to 4.95 ± 0.35 m/s. Meanwhile, the shear wave velocity of the corneal implant bed was lower than that of the implanted sheet. Therefore, this study reports the first biomechanical measurement of corneal grafts based on the OCE technique, which might provide a potential tool for the postoperative evaluation of clinical patients.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- School of Mathematics and Physics, University of Science and Technology Beijing, Beijing, China.
- Key Laboratory for Optoelectronic Information Perception and Instrumentation of Jiangxi Province, Nanchang Hangkong University, Nanchang, P. R. China.
ORCID-Profile: Gang Shi, Yubao Zhang
Förderung
- the National Key Research and Development Project, China
- National Natural Science Foundation of China
Zitieren
APA
Shi, G., Zhang, Y., Ai, S., Wang, Y., Li, Y., He, X., & Zheng, X. (2024). In Vivo Imaging and Evaluation of Corneal Biomechanics After Corneal Transplantation by Optical Coherence Elastography. Journal of Biophotonics. https://doi.org/10.1002/jbio.202400207
Vancouver
Shi G, Zhang Y, Ai S, Wang Y, Li Y, He X, et al. In Vivo Imaging and Evaluation of Corneal Biomechanics After Corneal Transplantation by Optical Coherence Elastography. Journal of Biophotonics. 2024. doi:10.1002/jbio.202400207
BibTeX
@article{Shi2024,
author = {Shi, Gang and Zhang, Yubao and Ai, Sizhu and Wang, Yidi and Li, Yingji and He, Xingdao and Zheng, Xinhe},
title = {In Vivo Imaging and Evaluation of Corneal Biomechanics After Corneal Transplantation by Optical Coherence Elastography},
journal = {Journal of Biophotonics},
year = {2024},
doi = {10.1002/jbio.202400207}
}
EUVIMED