Estimating Visual Acuity Without a Visual Acuity Chart
Translational Vision Science & Technology · 18.09.2024 · 13 (9) · 20
DOI: 10.1167/tvst.13.9.20 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Translational Vision Science & Technology, erschienen am 18.09.2024. Verfasst von Yueh-Hsun Wu und 9 weiteren Autor:innen. Beteiligte Einrichtung: College of Optometry, The Ohio State University, Columbus, OH, USA. Hauptthemen laut MEDLINE: Visual Acuity, Vision Tests. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NEI NIH HHS.
Abstract (Originalsprache)
Purpose
This study explored whether visual acuity (VA) can be inferred from self-reported ability to recognize everyday objects using a set of yes/no questions.
Methods
Participants answered 100 yes/no questions designed to assess their ability to recognize familiar objects at typical viewing distances, such as distinguishing between a full moon and a half moon on a clear night. The questions demanded VA ranging from normal to severe vision impairment. Responses were analyzed using item response theory, and the results were compared with participants' VA values.
Results
We recruited 385 participants from 4 sites in the United States. Participants had a mean age of 56.7 years with VA ranging from -0.3 to 2.0 logarithm of the minimum angle of resolution (logMAR) (mean = 0.58). A strong relationship was observed between participants' estimated vision ability and their VA (r = -0.72). The linear relationship can be used to predict each participant's VA based on their estimated vision ability. The average signed and unsigned prediction errors were 0 and 0.24 logMAR, respectively, with a coefficient of repeatability of 0.59 logMAR between the estimated VA and measured VA. The same linear function was used to determine the VA limit required for each question. For instance, the VA limit for the moon question was 1.0 logMAR.
Conclusions
Yes/no questions about everyday visual activities have the potential to estimate an individual's VA. Future refinements may enhance reliability. Translational Relevance: The survey provides insights into the real-world visual capabilities of people with low vision, making it potentially useful for telehealth applications.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- College of Optometry, The Ohio State University, Columbus, OH, USA.
- Department of Psychology, University of Minnesota, Minneapolis, MN, USA.
- Wilmer Eye Institute, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
- Department of Psychology, Northeastern University, Boston, MA, USA.
- The New England College of Optometry, Boston, MA, USA.
- Measurement and Statistics, College of Education, University of Washington, Seattle, WA, USA.
Förderung
- NEI NIH HHS
Zitieren
APA
Wu, Y. H., Yu, D., Goldstein, J. E., Kwon, M., Gobeille, M., Watson, E., Waked, L., Gage, R., Wang, C., & Legge, G. E. (2024). Estimating Visual Acuity Without a Visual Acuity Chart. Translational Vision Science & Technology, 13(9), 20. https://doi.org/10.1167/tvst.13.9.20
Vancouver
Wu YH, Yu D, Goldstein JE, Kwon M, Gobeille M, Watson E, et al. Estimating Visual Acuity Without a Visual Acuity Chart. Translational Vision Science & Technology. 2024;13(9):20. doi:10.1167/tvst.13.9.20
BibTeX
@article{Wu2024,
author = {Wu, Yueh-Hsun and Yu, Deyue and Goldstein, Judith E and Kwon, MiYoung and Gobeille, Micaela and Watson, Emily and Waked, Luc and Gage, Rachel and Wang, Chun and Legge, Gordon E},
title = {Estimating Visual Acuity Without a Visual Acuity Chart},
journal = {Translational Vision Science & Technology},
year = {2024},
volume = {13},
number = {9},
pages = {20},
doi = {10.1167/tvst.13.9.20}
}