EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Repeatability of a Virtual Reality Headset Perimeter in Glaucoma and Ocular Hypertensive Patients

Rafaella Nascimento E Silva, Julia A Kim, Yihao Li, Chen Chen, Anisa F Chaudhry, Andrew R Berneshawi, Miao Zhang, Adam Villarreal, Jocelyn Liu, Ann Shue, Dolly S Chang, Robert T Chang

Translational Vision Science & Technology · 2024

DOI: 10.1167/tvst.13.6.14 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Translational Vision Science & Technology, 2024. Verfasst von Rafaella Nascimento E Silva und 11 weiteren Autor:innen. Beteiligte Einrichtung: Genentech, Inc., South San Francisco, CA, USA. Hauptthemen laut MEDLINE: Ocular Hypertension, Virtual Reality, Visual Field Tests, Glaucoma. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0). Gefördert von: NEI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

The VisuALL S is an automated, static threshold, virtual reality-based perimeter for mobile evaluation of the visual field. We examined same-day and 3-month repeatability.

Methods

Adult participants with a diagnosis of glaucoma or ocular hypertension underwent two VisuALL 24-2 Normal T- Full threshold strategy tests at baseline and one additional exam at 3 months for each eligible eye. Spearman, intraclass correlation coefficients (ICCs), and Bland-Altman plots were used to assess the correlation of individual point sensitivities and mean deviation (MD) among three tests.

Results

Eighty-eight eyes (44 participants) were included. Average age was 68.1 ± 14.3 years, and 60.7% were male. VisuALL MD was highly correlated between tests (intravisit: r = 0.89, intervisit: r = 0.82; P < 0.001 for both). Bland-Altman analysis showed an average difference in intravisit MD of -0.67 dB (95% confidence interval [CI], -6.04 to 4.71 dB) and -0.15 dB (95% CI, -8.04 to 7.73 dB) for intervisit exams. Eight-five percent of pointwise intravisit ICCs were above 0.75 (range, 0.63 to 0.93), and 65% of pointwise intervisit ICCs were above 0.75 (range, 0.55 to 0.91).

Conclusions

VisuALL demonstrated high correlation of MD between tests and good repeatability for individual point sensitivities among three tests in 3 months, except at the points around the blind spot and superiorly. Translational Relevance: The preliminary reproducibility results for VisuALL are encouraging. Its portable design makes it a potentially useful tool for patients with glaucoma, enabling more frequent assessments both at home and in clinical settings.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Ocular HypertensionVirtual RealityVisual Field TestsGlaucomaVisual FieldsHumansMaleFemaleAgedReproducibility of ResultsMiddle AgedAged, 80 and overIntraocular PressureProspective Studies

Autor:innen und Institutionen

  • Genentech, Inc., South San Francisco, CA, USA.
  • Byers Eye Institute, Stanford University School of Medicine, Palo Alto, CA, USA.

Förderung

  • NEI NIH HHS

Zitieren

APA

Nascimento E Silva, R., Kim, J. A., Li, Y., Chen, C., Chaudhry, A. F., Berneshawi, A. R., Zhang, M., Villarreal, A., Liu, J., Shue, A., Chang, D. S., & Chang, R. T. (2024). Repeatability of a Virtual Reality Headset Perimeter in Glaucoma and Ocular Hypertensive Patients. Translational Vision Science & Technology. https://doi.org/10.1167/tvst.13.6.14

Vancouver

Nascimento E Silva R, Kim JA, Li Y, Chen C, Chaudhry AF, Berneshawi AR, et al. Repeatability of a Virtual Reality Headset Perimeter in Glaucoma and Ocular Hypertensive Patients. Translational Vision Science & Technology. 2024. doi:10.1167/tvst.13.6.14

BibTeX
@article{NascimentoESilva2024,
  author = {Nascimento E Silva, Rafaella and Kim, Julia A and Li, Yihao and Chen, Chen and Chaudhry, Anisa F and Berneshawi, Andrew R and Zhang, Miao and Villarreal, Adam and Liu, Jocelyn and Shue, Ann and Chang, Dolly S and Chang, Robert T},
  title = {Repeatability of a Virtual Reality Headset Perimeter in Glaucoma and Ocular Hypertensive Patients},
  journal = {Translational Vision Science & Technology},
  year = {2024},
  doi = {10.1167/tvst.13.6.14}
}
Kostenlos starten →