EUVIMEDEUVIMED entdecken
VergleichsstudieOpen Access · CC BY 4.0

Intraday repeatability of macular layers measurements in glaucomatous and non-glaucomatous patients using spectral-domain optical coherence tomography

Vadim Makhmutov, Werner Adler, Philomena A Wawer Matos, Adam Kopecky, Jan Nemcansky, Alexander C Rokohl, Ludwig M Heindl

Graefe's Archive for Clinical and Experimental Ophthalmology · 2024

DOI: 10.1007/s00417-024-06498-7 ↗

Kurz gefasst

Vergleichsstudie in der Zeitschrift Graefe's Archive for Clinical and Experimental Ophthalmology, 2024. Verfasst von Vadim Makhmutov und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Faculty of Medicine and University Hospital of Cologne, University of Cologne, Cologne, Germany. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Intraocular Pressure, Retinal Ganglion Cells, Nerve Fibers. Die Arbeit nennt 35 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Deutsche Forschungsgemeinschaft, Medizinische Fakultät, Universität zu Köln, University Hospital in Ostrava.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To assess the intraday repeatability of macular architecture measurements in glaucomatous and non-glaucomatous patients using spectral-domain optical coherence tomography (SD-OCT) and to evaluate the independence from intraindividual intraocular pressure (IOP) fluctuations.

Methods

In this single-center, time-point comparison study, 88 eyes with glaucoma, 53 eyes with ocular hypertension (OHT), and 253 healthy eyes underwent two standardized SD-OCT and intraocular pressure (IOP) measurements on the same day with a 5-h time gap. Bland–Altman plots, intraclass correlation coefficients (ICC), and random-effects model were used to analyze repeatability of entire retinal thickness, retinal nerve fiber layer, ganglion cell layer, inner plexiform layer, and inner nuclear layer measurements.

Results

Intraday measurements were highly reproducible in all 3 groups. ICC were greater than 0.90, respectively. The pairwise comparisons of morphometric parameters showed a statistically significant difference (P < 0.001, respectively) between groups (glaucoma vs. control, glaucoma vs. OHT) and a significant influence of time points. No correlation was found between IOP fluctuations and morphometric parameters ( P > 0.05, respectively), except for a weak positive correlation with GCL (rho = 0.109, P = 0.031).

Conclusions

The evaluation of macular morphometric parameters of SD-OCT showed a high intraday repeatability and an excellent degree of agreement in glaucoma, ocular hypertension, and healthy groups. The fixed effects of time points were statistically significant. Except for a weak positive correlation of ganglion cell layer, variability did not appear to be affected by intraday IOP changes. Additional research is required to fully understand the impact of IOP fluctuations on macular morphometric parameters, considering the small observed IOP changes.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, Optical CoherenceIntraocular PressureRetinal Ganglion CellsNerve FibersMacula LuteaGlaucomaHumansFemaleMaleMiddle AgedReproducibility of ResultsAgedTonometry, OcularOcular HypertensionAdultVisual FieldsFollow-Up Studies

Stichwörter der Autor:innen

Glaucoma progression analysisPosterior pole analysisSpectral-domain optical coherence tomography

Autor:innen und Institutionen

  • Department of Ophthalmology, Faculty of Medicine and University Hospital of Cologne, University of Cologne, Cologne, Germany.
  • Department of Medical Informatics, Biometry, and Epidemiology, Friedrich-Alexander, University Erlangen-Nuremberg, Erlangen, Germany.
  • Clinic of Ophthalmology, University Hospital Ostrava, Ostrava, Czech Republic. adam.kopecky@winet.cz.
  • Department of Craniofacial Surgery, University of Ostrava - Faculty of Medicine, Ostrava, Czech Republic. adam.kopecky@winet.cz.
  • Clinic of Ophthalmology, University Hospital Ostrava, Ostrava, Czech Republic.
  • Department of Craniofacial Surgery, University of Ostrava - Faculty of Medicine, Ostrava, Czech Republic.

Förderung

  • Deutsche Forschungsgemeinschaft
  • Medizinische Fakultät, Universität zu Köln
  • University Hospital in Ostrava

Zitieren

APA

Makhmutov, V., Adler, W., Matos, P. A. W., Kopecky, A., Nemcansky, J., Rokohl, A. C., & Heindl, L. M. (2024). Intraday repeatability of macular layers measurements in glaucomatous and non-glaucomatous patients using spectral-domain optical coherence tomography. Graefe's Archive for Clinical and Experimental Ophthalmology. https://doi.org/10.1007/s00417-024-06498-7

Vancouver

Makhmutov V, Adler W, Matos PAW, Kopecky A, Nemcansky J, Rokohl AC, et al. Intraday repeatability of macular layers measurements in glaucomatous and non-glaucomatous patients using spectral-domain optical coherence tomography. Graefe's Archive for Clinical and Experimental Ophthalmology. 2024. doi:10.1007/s00417-024-06498-7

BibTeX
@article{Makhmutov2024,
  author = {Makhmutov, Vadim and Adler, Werner and Matos, Philomena A Wawer and Kopecky, Adam and Nemcansky, Jan and Rokohl, Alexander C and Heindl, Ludwig M},
  title = {Intraday repeatability of macular layers measurements in glaucomatous and non-glaucomatous patients using spectral-domain optical coherence tomography},
  journal = {Graefe's Archive for Clinical and Experimental Ophthalmology},
  year = {2024},
  doi = {10.1007/s00417-024-06498-7}
}
Kostenlos starten →