EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Predicting the Extent of Damage in the Humphrey Field Analyzer 24-2 Visual Fields Using 10-2 Test Results in Patients With Advanced Glaucoma

Ryo Asaoka, Kenji Sugisaki, Toshihiro Inoue, Keiji Yoshikawa, Akiyasu Kanamori, Yoshio Yamazaki, Shinichiro Ishikawa, Kenichi Uchida, Aiko Iwase, Makoto Araie, for Advanced Glaucoma Study Members in Japan Glaucoma Society

Translational Vision Science & Technology · 2024

DOI: 10.1167/tvst.13.2.2 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Translational Vision Science & Technology, 2024. Verfasst von Ryo Asaoka und 10 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Seirei Hamamatsu General Hospital, Hamamatsu, Shizuoka, Japan. Hauptthemen laut MEDLINE: Visual Fields, Glaucoma. Die Arbeit nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To predict Humphrey Field Analyzer 24-2 test (HFA 24-2) results using 10-2 results.

Methods

A total of 175 advanced glaucoma eyes (175 patients) with HFA 24-2 mean deviation (MD24-2) of < -20 dB were prospectively followed up for five years using HFA 10-2 and 24-2 (twice and once in a year, respectively). Using all the HFA 24-2 and 10-2 test result pairs measured within three months (350 pairs from 85 eyes, training dataset), a formula to predict HFA 24-2 result using HFA 10-2 results was constructed using least absolute shrinkage and selection operator regression (LASSO). Using 90 different eyes (testing dataset), the absolute differences between the actual and LASSO-predicted MD24-2 and that between the slopes calculated using five actual and LASSO-predicted MD24-2 values, were adopted as the prediction error. Similar analyses were performed for the mean total deviation values (mTD) of the superior (or inferior) hemifield [hemi-mTDsup.24-2(-hemi-mTDinf.24-2)].

Results

The prediction error for the LASSO-predicted MD24-2 and its slope were 2.98 (standard deviation [SD] = 1.90) dB and 0.32 (0.33) dB/yr, respectively. The LASSO-predicted hemi-mTDsup.24-2 (hemi-mTDinf.24-2), and its slope were 3.02 (2.89) and 3.76 (2.72) dB, and 0.37 (0.41) and 0.44 (0.38) dB/year, respectively. These prediction errors were within two times SD of repeatability of the simulated stable HFA 24-2 VF parameter series.

Conclusions

HFA 24-2 results could be predicted using the paired HFA 10-2 results with reasonable accuracy using LASSO in patients with advanced glaucoma. Translational Relevance: It is useful to predict HFA24-2 test from HFA10-2 test, when the former is not available, in advanced glaucoma.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Visual FieldsGlaucomaHumansVisual Field TestsEye

Autor:innen und Institutionen

  • Department of Ophthalmology, Seirei Hamamatsu General Hospital, Hamamatsu, Shizuoka, Japan.
  • Seirei Christopher University, Hamamatsu, Shizuoka, Japan.
  • The Graduate School for the Creation of New Photonics Industries, Shizuoka, Japan.
  • Organization for Innovation and Social Collaboration, National University Corporation Shizuoka University, Hamamatsu, Shizuoka, Japan.
  • Department of Ophthalmology, International University of Health and Welfare, Mita Hospital, Tokyo, Japan.
  • Department of Ophthalmology, University of Tokyo Graduate School of Medicine, Tokyo, Japan.

Zitieren

APA

Asaoka, R., Sugisaki, K., Inoue, T., Yoshikawa, K., Kanamori, A., Yamazaki, Y., Ishikawa, S., Uchida, K., Iwase, A., Araie, M., & for Advanced Glaucoma Study Members in Japan Glaucoma Society (2024). Predicting the Extent of Damage in the Humphrey Field Analyzer 24-2 Visual Fields Using 10-2 Test Results in Patients With Advanced Glaucoma. Translational Vision Science & Technology. https://doi.org/10.1167/tvst.13.2.2

Vancouver

Asaoka R, Sugisaki K, Inoue T, Yoshikawa K, Kanamori A, Yamazaki Y, et al. Predicting the Extent of Damage in the Humphrey Field Analyzer 24-2 Visual Fields Using 10-2 Test Results in Patients With Advanced Glaucoma. Translational Vision Science & Technology. 2024. doi:10.1167/tvst.13.2.2

BibTeX
@article{Asaoka2024,
  author = {Asaoka, Ryo and Sugisaki, Kenji and Inoue, Toshihiro and Yoshikawa, Keiji and Kanamori, Akiyasu and Yamazaki, Yoshio and Ishikawa, Shinichiro and Uchida, Kenichi and Iwase, Aiko and Araie, Makoto and for Advanced Glaucoma Study Members in Japan Glaucoma Society, for Advanced Glaucoma Study Members in Japan Glaucoma Society},
  title = {Predicting the Extent of Damage in the Humphrey Field Analyzer 24-2 Visual Fields Using 10-2 Test Results in Patients With Advanced Glaucoma},
  journal = {Translational Vision Science & Technology},
  year = {2024},
  doi = {10.1167/tvst.13.2.2}
}
Kostenlos starten →