Performance of virtual reality game–based automated perimetry in patients with childhood glaucoma
Journal of American Association for Pediatric Ophthalmology and Strabismus · 2023-12 · 27 (6) · 325.e1-325.e6
DOI: 10.1016/j.jaapos.2023.08.014 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of American Association for Pediatric Ophthalmology and Strabismus, 2023-12. Verfasst von Bo Wang und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Duke University Medical Center, Durham, North Carolina; Wilmer Eye Institute, Johns Hopkins Hospital, Baltimore, Marylan…. Hauptthemen laut MEDLINE: Visual Field Tests, Glaucoma. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 17 Literaturangaben.
Abstract (Originalsprache)
PURPOSE: To evaluate VisuALL, a game-based automated perimetry device, utilizing virtual reality (VR) goggles, in a cohort of patients with childhood glaucoma. METHODS: In this prospective series, the results of consecutive patients with childhood glaucoma performing both VisuALL VR field (VRF) and Humphrey visual field (HVF) 24-2 testing were compared. A masked ophthalmologist graded both VRF and HVF tests for field defects (three clustered abnormal points in total or pattern deviation plot). VRF testing was performed binocularly and with the child's own spectacles. The two devices were assessed with respect to agreement of (1) global indices, such as mean deviation (MD) and pattern standard deviation (PSD), (2) point-by-point sensitivity, and (3) the ability to detect visual field defects determined by a grader. RESULTS: A total of 39 children (77 eyes) were enrolled, with mean age 14.1 ± 3.6 years; 3 patients (5 eyes) could not complete the HVF. Average HVF MD was -6.3 ± 6.4 dB. There was strong correlation between VRF and HVF for MD (R = 0.68, P < 0.001), PSD (R = 0.78, P < 0.001), and point-by-point sensitivity (R = 0.63, P < 0.001). Bland Altman analysis showed no systematic difference between VRF and HVF in assessing MD and PSD. Of 72 eyes having results for both modalities, 63 (87.5%) had agreement between VRF and HVF with respect to the presence/absence of any field defect, and 52 (72.2%) had agreement regarding the presence/absence of fixation-threatening field loss. CONCLUSIONS: VRF is comparable to the gold standard HVF in both identification and quantification of visual field deficits in pediatric glaucoma patients and may offer a valuable supplement or alternative to standard automated perimetry.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Ophthalmology, Duke University Medical Center, Durham, North Carolina; Wilmer Eye Institute, Johns Hopkins Hospital, Baltimore, Maryland.
- Department of Ophthalmology, Duke University Medical Center, Durham, North Carolina.
- Department of Ophthalmology, Duke University Medical Center, Durham, North Carolina. Electronic address: sharon.freedman@duke.edu.
Zitieren
APA
Wang, B., Alvarez-Falcón, S., El-Dairi, M., & Freedman, S. F. (2023). Performance of virtual reality game–based automated perimetry in patients with childhood glaucoma. Journal of American Association for Pediatric Ophthalmology and Strabismus, 27(6), 325.e1-325.e6. https://doi.org/10.1016/j.jaapos.2023.08.014
Vancouver
Wang B, Alvarez-Falcón S, El-Dairi M, Freedman SF. Performance of virtual reality game–based automated perimetry in patients with childhood glaucoma. Journal of American Association for Pediatric Ophthalmology and Strabismus. 2023;27(6):325.e1-325.e6. doi:10.1016/j.jaapos.2023.08.014
BibTeX
@article{Wang2023,
author = {Wang, Bo and Alvarez-Falcón, Samuel and El-Dairi, Mays and Freedman, Sharon F},
title = {Performance of virtual reality game–based automated perimetry in patients with childhood glaucoma},
journal = {Journal of American Association for Pediatric Ophthalmology and Strabismus},
year = {2023},
volume = {27},
number = {6},
pages = {325.e1--325.e6},
doi = {10.1016/j.jaapos.2023.08.014}
}