The Strain Response to Intraocular Pressure Increase in the Lamina Cribrosa of Control Subjects and Glaucoma Patients
Translational Vision Science & Technology · 04.12.2024 · 13 (12) · 7
DOI: 10.1167/tvst.13.12.7 ↗Kurz gefasst
Fachartikel in der Zeitschrift Translational Vision Science & Technology, erschienen am 04.12.2024. Verfasst von Cameron A Czerpak und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Mechanical Engineering, The Johns Hopkins University, Baltimore, MD, USA. Hauptthemen laut MEDLINE: Intraocular Pressure, Tomography, Optical Coherence, Optic Disk, Glaucoma. Die Arbeit wurde bisher 8-mal zitiert (Crossref) und nennt 41 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: NEI NIH HHS.
Abstract (Originalsprache)
Purpose
The purpose of this study was to measure biomechanical strains in the lamina cribrosa (LC) of living human eyes undergoing intraocular pressure (IOP) increase.
Methods
Healthy control subjects and patients with glaucoma underwent optical coherence tomographic (OCT) imaging of the LC before and after wearing of swim goggles that increased IOP (57 image pairs, 39 persons). Digital volume correlation was used to measure biomechanical strains in optic nerve head tissue and change in depth of the anterior border of the LC.
Results
The mean IOP increase in both glaucoma and control eyes was 7.1 millimeters of mercury (mm Hg) after application of the goggles. Among glaucoma eyes, strains that were significant were: contractile Ezz (average = -0.33%, P = 0.0005), contractile Eθθ (average = -0.23%, P = 0.03), Emax (average = 0.83%, P < 0.0001), and Γmax (average = 0.95%, P < 0.0001), whereas the average anterior LC depth (ALD) decreased by 2.39 µm (anterior; P = 0.0002). In glaucoma eyes, shear strain Ezθ was greater with worse mean deviation (MD) and visual function index (P = 0.044 and P = 0.006, respectively, multivariate models). Strain compliance for Erθ, Ezθ, and Eθθ all increased with greater MD worsening prior to imaging (P = 0.04, P = 0.007, and P = 0.03).
Conclusions
LC strains were measurable 20 minutes after IOP increase, producing axial compression and greater peripheral strain than centrally. Some strain compliances were greater with worse existing visual field loss or with more progressive past field loss. Translational Relevance: Biomechanical strains are related to measures of glaucoma damage, supporting the hypothesis that optic nerve head biomechanical responses represent a noninvasive biomarker for glaucoma.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Mechanical Engineering, The Johns Hopkins University, Baltimore, MD, USA.
- Wilmer Ophthalmological Institute, Department of Ophthalmology, Johns Hopkins University School of Medicine, Baltimore, MD, USA.
- Meharry Medical College, Nashville, TN, USA.
Förderung
- NEI NIH HHS
Zitieren
APA
Czerpak, C. A., Kashaf, M. S., Zimmerman, B. K., Mirville, R., Gasquet, N. C., Quigley, H. A., & Nguyen, T. D. (2024). The Strain Response to Intraocular Pressure Increase in the Lamina Cribrosa of Control Subjects and Glaucoma Patients. Translational Vision Science & Technology, 13(12), 7. https://doi.org/10.1167/tvst.13.12.7
Vancouver
Czerpak CA, Kashaf MS, Zimmerman BK, Mirville R, Gasquet NC, Quigley HA, et al. The Strain Response to Intraocular Pressure Increase in the Lamina Cribrosa of Control Subjects and Glaucoma Patients. Translational Vision Science & Technology. 2024;13(12):7. doi:10.1167/tvst.13.12.7
BibTeX
@article{Czerpak2024,
author = {Czerpak, Cameron A and Kashaf, Michael Saheb and Zimmerman, Brandon K and Mirville, Rebecca and Gasquet, Nicolas C and Quigley, Harry A and Nguyen, Thao D},
title = {The Strain Response to Intraocular Pressure Increase in the Lamina Cribrosa of Control Subjects and Glaucoma Patients},
journal = {Translational Vision Science & Technology},
year = {2024},
volume = {13},
number = {12},
pages = {7},
doi = {10.1167/tvst.13.12.7}
}
EUVIMED