EUVIMEDEUVIMED entdecken
Crossref

The repeatability of macular and peripapillary vessel density in participants with different severities of glaucoma

Yun Hsia iD, Tsing-Hong Wang, Jehn-Yu Huang, Chien-Chia Su iD

Ophthalmic and Physiological Optics · 2025

DOI: 10.1111/opo.13448 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Ophthalmic and Physiological Optics, 2025. Verfasst von Yun Hsia und 3 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, National Taiwan University Hospital, Taipei, Taiwan. Hauptthemen laut MEDLINE: Tomography, Optical Coherence, Retinal Vessels, Macula Lutea, Glaucoma, Open-Angle. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 55 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To investigate the repeatability of optical coherence tomography angiography (OCTA) parameters in participants with different severities of glaucoma.

Methods

Subjects with open‐angle glaucoma were enrolled prospectively and categorised into mild (mean deviation [MD] of 24–2 visual field test ≥ −6 dB), moderate to advanced (−6 > MD ≥ −20 dB) and severe glaucoma groups (MD < −20 dB). OCTA was performed three times within a single visit to obtain superficial and deep macular vessel density (VD) and peripapillary vessel and capillary density. The association between the coefficient of variation (CoV) and intraclass correlation coefficient (ICC) of these OCTA parameters and glaucoma severity (MD, the thickness of the retinal nerve fibre layer and the ganglion cell complex) was analysed, along with factors associated with the CoV of OCTA parameters.

Results

A total of 57 mild, 92 moderate to advanced and 39 severe glaucomatous eyes were included. CoV for superficial ( p < 0.001) and deep macular VD ( p < 0.001) and peripapillary VD ( p = 0.004) increased with glaucoma severity. Greater CoV for superficial and deep macular VD and peripapillary VD was associated with worse MD and scan quality index in multivariable analysis. The association between a higher CoV of superficial and deep macular VD and worse MD was only noticeable in participants with a scan quality index

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, Optical CoherenceRetinal VesselsMacula LuteaGlaucoma, Open-AngleOptic DiskVisual FieldsIntraocular PressureFluorescein AngiographyHumansMaleFemaleProspective StudiesMiddle AgedRetinal Ganglion CellsAgedNerve FibersReproducibility of ResultsSeverity of Illness IndexVisual Field Tests

Stichwörter der Autor:innen

advanced glaucomaglaucomaintrasession variabilitymacular vessel densityoptical coherence tomography angiographyperipapillary vessel density

Autor:innen und Institutionen

  • Department of Ophthalmology, National Taiwan University Hospital, Taipei, Taiwan.
  • College of Medicine, National Taiwan University, Taipei, Taiwan.
  • Department of Ophthalmology, National Taiwan University Hospital Hsinchu Branch, Hsinchu, Taiwan.

ORCID-Profile: Yun Hsia, Chien-Chia Su

Zitieren

APA

Hsia, Y., Wang, T. H., Huang, J. Y., & Su, C. C. (2025). The repeatability of macular and peripapillary vessel density in participants with different severities of glaucoma. Ophthalmic and Physiological Optics. https://doi.org/10.1111/opo.13448

Vancouver

Hsia Y, Wang TH, Huang JY, Su CC. The repeatability of macular and peripapillary vessel density in participants with different severities of glaucoma. Ophthalmic and Physiological Optics. 2025. doi:10.1111/opo.13448

BibTeX
@article{Hsia2025,
  author = {Hsia, Yun and Wang, Tsing-Hong and Huang, Jehn-Yu and Su, Chien-Chia},
  title = {The repeatability of macular and peripapillary vessel density in participants with different severities of glaucoma},
  journal = {Ophthalmic and Physiological Optics},
  year = {2025},
  doi = {10.1111/opo.13448}
}
Kostenlos starten →